Set-Th-Eqpt; Table 9-54 Set-Th-Eqpt Syntax Description - Cisco 15216 EDFA2 Operation Manual

Cisco systems optical network system operations guide
Table of Contents

Advertisement

Chapter 9
TL1 Commands
Table 9-53 SET-TH-ENV Syntax Description (continued)
Parameter
threshholdtype
and
thresholdvalue
pairs

9.7.47 SET-TH-EQPT

Command
SET-TH-EQPT
Sets general threshold values for the ONS 15216 EDFA2.
Syntax
SET-TH-EQPT:[<tid>]:<aid>:<ctag>::<thresholdtype>,<thresholdvalue>[,,];
Example 9-50 SET-TH-EQPT Command
Amp01:ONS15216 EDFA2> SET-TH-EQPT:Amp01:ALL:123::MAXCTMP,60;

Table 9-54 SET-TH-EQPT Syntax Description

Parameter
aid
78-16033-01
F I N A L D R A F T - C I S C O C O N F I D E N T I A L
Syntax
PWRBUSMIN
PWRBUSMAX
Syntax
EQPT
ALL
Description
Type of threshold that is to be set. The threshold is set to the
thresholdvalue that follows the comma. Possible to specify
values for one or more of the following:
Power bus minimum voltage
(cerent15216EdfaPowerBusDCVoltageMin).
thresholdvalue can be between 350 and 700, with default of
400, in units of –10 VDC.
The power bus threshold has a 1.0V tolerance and a 1.0V
hysteresis. If the minimum threshold is configured at 400 (-40
VDC), the alarm will not raise until the voltage goes below -39
VDC and will not clear until the voltage goes above -41VDC.
Power bus maximum voltage
(cerent15216EdfaPowerBusDCVoltageMax).
thresholdvalue can be between 350 and 700, with default of
570, in units of –10 VDC.
The power bus threshold has a 1.0V tolerance and a 1.0V
hysteresis. If the maximum threshold is configured at 570 (-57
VDC), the alarm will not raise until the voltage goes above -58
VDC and will not clear until the voltage goes below -56 VDC.
Description
EQPT and ALL have same input effect.
General parameters of the ONS 15216 EDFA2 (not directly
affecting optical signal or power bus).
Any or all of the preceding (command input only).
Cisco ONS 15216 EDFA2 Operations Guide