Set Date and Time

8.4 Set Date and Time
Use the ED-DAT command (see
cannot be set using TL1. The time setting is restricted to universal coordinated time (UTC) according to
the following syntax:
ED-DAT:[<tid>]::<ctag>::<utcdate>,<utctime>;
The utcdate and utctime entries must follow this format: yyyy-mm-dd,hh-mm-ss. See
Example 8-4
sidtidname:ONS15216 EDFA2> ED-DAT:::120::2002-04-18,02-24-55;

8.5 Set Power Bus Mode (Simplex or Duplex)

The ONS 15216 EDFA2 allows users to set a simplex (one power source–Bus A) or duplex (redundant
power source–Bus A and Bus B) Power Bus mode. The default mode is duplex. Use the ED-ENV
command (see
following syntax:
ED-ENV:[<tid>]:<aid>:<ctag>:::PWRBUSMODE=<pwrbusmode>;
The pwrbusmode value can be SIMPLEX or DUPLEX. See
Example 8-5
sidtidname:ONS15216 EDFA2> ED-ENV::ALL:121:::PWRBUSMODE=SIMPLEX;

8.6 Verify Amplifier Operational Status

To ensure that the amplifier is working correctly on the optical level, you must verify the amplifier
operational status. Use the RTRV-DWDM command (see
verify amplifier operational status according to the following syntax:
RTRV-DWDM:[<tid>]:<aid>:<ctag>;
<sid> <date> <time>
M
<ctag>
>,OUTPWRDBM=<outputpowerdbm>,PUMP1CTRLMODE=<pump1ctrlmode>,PUMP1CTRLVALUE=<pump1ctrlvalue>
,PUMP2CTRLMODE=<pump2ctrlmode>,PUMP2CTRLVALUE=<pump1ctrlvalue>,OVERALLGAIN=<gain>,PREATT=<
preatt>"
Example 8-6
Example 8-6
sidtidname:ONS15216 EDFA2> RTRV-DWDM::ALL:122;
sidtidname 2002-07-11 10:20:05
M
122 COMPLD
"1:INPWRMICROW=264,INPWRDBM=-1578,OUTPWRMILLIW=172,OUTPWRDBM=237,PUMP1CTRLMODE=GAINTEMP
,PUMP1CTRLVALUE=169,PUMP2CTRLMODE=GAINTEMP,PUMP2CTRLVALUE=169,OVERALLGAIN=169,PREATT=60"
;
Cisco ONS 15216 EDFA2 Operations Guide
8-4
F I N A L D R A F T - C I S C O C O N F I D E N T I A L
Setting the Date and Time Using TL1
"ED-ENV" section on page
Setting the Power Bus Mode Using TL1
COMPLD
"<aid>:INPWRMICROW=<inputpoweruw>,INPWRDBM=<inputpowerdbm>,OUTPWRMILLIW=<outputpowermw
displays sample output of this command.
Verifying the Amplifier Operations Status Using TL1
"ED-DAT" section on page
9-18) to set the desired power bus mode according to the
"RTRV-DWDM" section on page
Chapter 8
Provisioning Using TL1
9-16) to set the date and time. A time zone
Example
8-5.
Example
8-4.
9-48) to
78-16033-01

Advertisement

Table of Contents
loading

Table of Contents