Tables and Groups

5.4.1 CfgGroup Table

The cerent15216EdfaCfgGroup table is used to set or get alarm threshold configuration. The associated
table command provides a summary of all alarm thresholds. See
more information on alarm thresholds, see the
Table 5-6
Variable
cerent15216EdfaCfgSaved
cerent15216EdfaLpoutSetp
oint
cerent15216EdfaLpoutDevi
ation
cerent15216EdfaLpoutHyst
eresis
cerent15216EdfaLOSThres
hold
cerent15216EdfaLOSHyster
esis
cerent15216EdfaCtmpMin
cerent15216EdfaCtmpMinH
ysteresis
cerent15216EdfaCtmpMax
cerent15216EdfaCtmpMax
Hysteresis
Cisco ONS 15216 EDFA2 Operations Guide
5-12
F I N A L D R A F T - C I S C O C O N F I D E N T I A L
cerent15216EdfaCfgGroup Variable Descriptions
"Set Alarm Thresholds" section on page
Maximum
Syntax
Access
True Value
Read-only
Integer
Read-only
(0 to 1000)
Integer
Read-write
(0 to 1000)
Integer
Read-write
(0 to 1000)
Integer
Read-write
(–3100 to –1500)
Integer
Read-write
(0 to 1000)
Integer
Read-write
(–10 to 10)
Integer
Read-write
(0 to 10)
Integer
Read-write
(20 to 70)
Integer
Read-write
(0 to 10)
Chapter 5
SNMP MIB Installation and Configuration
Table 5-6
for variable definitions. For
Description
Indicates whether the current
configuration has been saved.
Loss of pump output power set point
for the Lpout alarm (*10 mW).
This is set when the
cerent15216EdfaPumpCfgConstOutP
ower attribute is set for pump 2.
Amount that the output power must
deviate from the set point to set the
Lpout alarm (*100 dB).
Amount that the output power must
move towards the set point before the
Lpout alarm is cleared (*100 dB).
Loss of signal threshold (*100 dBm).
Amount above
cerent15216EdfaLOSThreshold that
the input signal must rise before the
Lpin alarm is cleared (*100 dB).
Minimum allowable case temperature
in degrees Celsius.
Amount above
cerent15216EdfaCtmpMin that the
case temperature must rise before the
Ctmp alarm is cleared in degrees
Celsius.
Maximum allowable case temperature
in degrees Celsius.
Amount below
cerent15216EdfaCtmpMax that the
case temperature must drop before the
Ctmp alarm is cleared in degrees
Celsius.
4-5.