Summary of Autonomous Alarms and Messages
F I N A L D R A F T - C I S C O C O N F I D E N T I A L
1. The messages for Loss of Signal (LOS), Gain Out of Range (GAIN), and Loss of Output Power (LPOUT) are prioritized (in
the order just listed) so that only one message can be delivered at one time. For example, if the ONS 15216 EDFA2 detects
both a loss of input signal and a loss of output power at the same time, it will deliver only the Loss of Signal (LOS) message
to the user. This prioritized filtering of alarms does not occur with the SNMP delivery of alarms of the ONS 15216 EDFA2.
2. A single power bus alarm is Minor. If the power system is in duplex mode and an alarm is raised on both power buses, the
second alarm is Critical.
Table 9-5 on page 9-4
Table 9-5
TL1 Autonomous
Message
REPT EVT DWDM
REPT EVT DWDM
REPT EVT DWDM
REPT EVT DWDM
REPT EVT DWDM
REPT EVT DWDM
REPT EVT DWDM
REPT EVT DWDM
REPT EVT DWDM
REPT EVT ENV
REPT EVT ENV
REPT EVT ENV
REPT EVT EQPT
REPT EVT EQPT
REPT EVT EQPT
REPT EVT EQPT
REPT EVT EQPT
Cisco ONS 15216 EDFA2 Operations Guide
9-4
summarizes the ONS 15216 EDFA2 autonomous events.
TL1 Autonomous Events
Condition Type
(condtype)
CTRLMODE1
CTRLMODE2
GAINCHGD
LOSHYSTCHGD
LOSTHCHGD
LPOUTCHGD
LPOUTDEVCHGD
LPOUTHYSTCHGD
PREATTCHGD
PWRBUSMAXCHGD Power Bus Max (voltage)
PWRBUSMINCHGD
PWRBUSMODE
MAXCTMPCHGD
MAXCTMPHYSTCHGD Max Ctmp (case temperature)
MINCTMPCHGD
MINCTMPHYSTCHGD Min Ctmp (case temperature)
CUTOVERRESET
Condition Descriptor
(conddescr)
Pump1 Control Mode
Changed
Pump2 Control Mode
Changed
Overall Gain Changed
LOS (loss of signal)
Hysteresis Changed
LOS (loss of signal)
Threshold Changed
Loss Of Output Power
Setpoint Changed
Lpout (loss of output
power) Deviation Changed
Lpout (loss of output
power) Hysteresis Changed
Pre-attenuation Changed
Changed
Power Bus Min (voltage)
Changed
Power Bus Mode Changed PWR-B
Max Case Temperature
Changed
Hysteresis Changed
Min Case Temperature
Changed
Hysteresis Changed
(Software) Reset After
Cutover
Chapter 9
TL1 Commands
Access
Condition
Identifier
Effect
(aid)
(condeff)
1
TC
1
TC
1
TC
1
TC
1
TC
1
TC
1
TC
1
TC
1
TC
PWR-A
TC
PWR-A
TC
TC
EQPT
TC
EQPT
TC
EQPT
TC
EQPT
TC
EQPT
TC
78-16033-01