Tables and Groups
For example, to change the value for Constant Pump Current mode, use the following steps:
Step 1
Set the pump value using cerent15216EdfaPumpCfgConstPumpCurrent attribute.
a.
b.
Repeat
Step 2
Set the pump mode of operation using cerent15216EdfaPumpCfgControlMode attribute.
Step 3
a.
b.
Repeat
Step 4
Example 5-7
mode to Constant Pump Current mode again for the settings to take effect.
Example 5-7
ash:hostname:ONS15216 EDFA2> snmp attribute set local cerent15216EdfaPumpCfgConstPumpCurrent 1
200
ash:hostname:ONS15216 EDFA2> snmp attribute set local cerent15216EdfaPumpCfgConstPumpCurrent 2
200
ash:hostname:ONS15216 EDFA2> snmp attribute set local cerent15216EdfaPumpCfgControlMode 1
constCurrent
ash:hostname:ONS15216 EDFA2> snmp attribute set local cerent15216EdfaPumpCfgControlMode 2
constCurrent
5.4.3 OverallStatusGroup Table
The cerent15216EdfaOverallStatusGroup table allows users to display the input and output of the
ONS 15216 EDFA2 amplifier.
table variables.
Cisco ONS 15216 EDFA2 Operations Guide
5-16
F I N A L D R A F T - C I S C O C O N F I D E N T I A L
Select pump 1.
Set the value.
Step 1
for pump 2.
Select pump 1.
Set the mode.
Step 3
for pump 2.
shows how to set the value for Constant Pump Current mode to be 200 mA and then set the
Changing Value for Constant Pump Current Mode
Table 5-8 on page 5-17
describes cerent15216EdfaOverallStatusGroup
Chapter 5
SNMP MIB Installation and Configuration
78-16033-01