Overallstatusgroup Table - Cisco 15216 EDFA2 Operation Manual

Cisco systems optical network system operations guide
Table of Contents

Advertisement

Tables and Groups
For example, to change the value for Constant Pump Current mode, use the following steps:
Step 1
Set the pump value using cerent15216EdfaPumpCfgConstPumpCurrent attribute.
a.
b.
Repeat
Step 2
Set the pump mode of operation using cerent15216EdfaPumpCfgControlMode attribute.
Step 3
a.
b.
Repeat
Step 4
Example 5-7
mode to Constant Pump Current mode again for the settings to take effect.
Example 5-7
ash:hostname:ONS15216 EDFA2> snmp attribute set local cerent15216EdfaPumpCfgConstPumpCurrent 1
200
ash:hostname:ONS15216 EDFA2> snmp attribute set local cerent15216EdfaPumpCfgConstPumpCurrent 2
200
ash:hostname:ONS15216 EDFA2> snmp attribute set local cerent15216EdfaPumpCfgControlMode 1
constCurrent
ash:hostname:ONS15216 EDFA2> snmp attribute set local cerent15216EdfaPumpCfgControlMode 2
constCurrent

5.4.3 OverallStatusGroup Table

The cerent15216EdfaOverallStatusGroup table allows users to display the input and output of the
ONS 15216 EDFA2 amplifier.
table variables.
Cisco ONS 15216 EDFA2 Operations Guide
5-16
F I N A L D R A F T - C I S C O C O N F I D E N T I A L
Select pump 1.
Set the value.
Step 1
for pump 2.
Select pump 1.
Set the mode.
Step 3
for pump 2.
shows how to set the value for Constant Pump Current mode to be 200 mA and then set the
Changing Value for Constant Pump Current Mode
Table 5-8 on page 5-17
describes cerent15216EdfaOverallStatusGroup
Chapter 5
SNMP MIB Installation and Configuration