Connect the alarm cable to the alarm system contacts:
Step 2
a.
b.
Refer to
3-6

3.5.2 Alarm LEDs

The ONS 15216 EDFA2 has five LEDs:
Three of these LEDs, POWER, FAIL, and LOS, are located at the left side of the front panel of the
ONS 15216 EDFA2. The two Ethernet LEDs are located at the top left and right sides of the Ethernet
socket. When the module is powered on, an LED test is performed.
3.5.2.1 POWER LED (Green)
The POWER LED is green. This LED functions as follows:
In the off condition, the first pair of alarm relay contacts in the RJ-45 connector changes from a normally
open condition to a closed condition. The LED and alarm automatically reset when the condition clears.
(For additional alarm contact closure information, see the
on page
3.5.2.2 FAIL LED (Red)
The FAIL LED is red. This LED functions as follows:
In the on condition, the second pair of alarm relay contacts in the RJ-45 connector changes from a
normally open to a closed condition. If an invalid input optical signal is applied to the
ONS 15216 EDFA2, the Fail LED is illuminated. The LED and alarm automatically reset when the
condition clears.
Cisco ONS 15216 EDFA2 Operations Guide
3-6
F I N A L D R A F T - C I S C O C O N F I D E N T I A L
Cisco ONS 15454 medium-dependent interface (MDI) wire wrap pins
Central office (CO) alarm panel
Table 3-2 on page 3-5
for information on the ONS 15216 EDFA2 alarm LEDs.
POWER
FAIL
LOS
Ethernet socket (2)
On: –48 VDC power is within tolerance. (Power Bus A and B are powered normally.)
Off: No –48 VDC power or power is out of tolerance from the internal power supply. (Power Bus A
and B are not powered.)
Flashing: Power Bus A or B (in duplex mode) has failed or is out of tolerance, or Power Bus A (in
simplex mode) is out of tolerance.
3-5.)
On: The laser pump bias, laser pump temperature, output power, gain, or case temperature is out of
tolerance. (A major internal failure has occurred.)
Off: The laser pump bias or laser pump temperature is in the specified range (or no –48 VDC power
is present).
for information concerning alarm contacts. Refer to