Alcatel-Lucent 1665 Installation Manual page 57

Data multiplexer (dmx)
Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Equipment and cable installation
............................................................................................................................................................................................................................................................
........................................................................................................................................................................................................................
8
Position one of the brackets along the left side of shelf 1. Secure with three bracket
mounting screws.
........................................................................................................................................................................................................................
9
Repeat
........................................................................................................................................................................................................................
10
Locate three spools (848919221), one fiber radius control module (321-1B), one right
fiber spool bracket (848919221) and three M4 X 6 bracket mounting screws (901340059)
for each shelf being installed.
........................................................................................................................................................................................................................
11
For each spool, put a nylach fastener through the middle. Then insert a pin halfway
through.
Note:
the fastener and prevent it from being assembled to the bracket.
........................................................................................................................................................................................................................
12
Line up the nylach fastener in one of the spools with the large holes on the top arm of the
bracket.
........................................................................................................................................................................................................................
13
Spin the spool until the peg on its back fits into the smaller hole on the arm of the bracket.
This will keep the spool from spinning any further.
........................................................................................................................................................................................................................
14
Push the pin until it is completely fastened.
........................................................................................................................................................................................................................
15
Repeat
........................................................................................................................................................................................................................
16
Attach one fiber radius control module to the bottom of each bracket.
........................................................................................................................................................................................................................
17
Position one of the brackets along the right side of shelf 1. Secure with 3 bracket mounting
screws.
........................................................................................................................................................................................................................
18
Repeat
............................................................................................................................................................................................................................................................
365-372-304R7.1
Issue 2 March 2008
Step 8
for all the other shelves being installed.
It is very important that the pin is not completely inserted. This will deform
Step 12
through
Step 14
Step 17
for all the other shelves being installed.
for all the spools, with three per bracket.
Fiber management installation (optional)
1 - 2 9