OC-3/12/48 Ring setup and testing: integration
procedures
............................................................................................................................................................................................................................................................
SFP/XFP optics
OC192LR2-C1
X10GxxC5
series
* LNW59, LNW502 do not use X10G56C5, X10G57C6, X10G58C8 and X10G59C5
........................................................................................................................................................................................................................
13
Select the proper LBO based on the value required and the comcode as listed below.
........................................................................................................................................................................................................................
14
Clean LC LBOs and install LBO assemblies in the OLIU IN connector.
........................................................................................................................................................................................................................
15
At the far end, connect the input optical fiber to the proper OLIU IN connector.
Requirement: The FAULT LED on the OLIU extinguishes.
........................................................................................................................................................................................................................
16
At the near end, connect the input optical fiber to the proper OLIU IN connector.
Requirement: The FAULT LED on the OLIU extinguishes.
........................................................................................................................................................................................................................
17
Disconnect the fiber cable from the OUT connector on the OLIU at one end of the span.
At the other end, verify that the associated FAULT LED is flashing, indicating a loss of
signal. Reconnect the fiber and repeat the process for the other direction of transmission.
........................................................................................................................................................................................................................
18
Enable communications with the adjacent Alcatel-Lucent 1665 DMX nodes.
Configuration -> DCC Terminations...
............................................................................................................................................................................................................................................................
365-372-304R7.1
Issue 2 March 2008
Circuit Pack
LNW59, LNW502
*
LNW59, LNW502,
LNW705
Code
Comcode
ABLCS-05.0
108279381
ABLCS-10.0
108279431
ABLCS-15.0
108279480
ABLCS-20.0
108279530
Received
LBO
Power (dBM)
(dB)
+4.0 to 0.0
15
0.0 to -7.0
10
-7.0 to -24.0
0
-8.0 to -24
15
Loss (dB)
5
10
15
20