Pluggable transmission module installation
............................................................................................................................................................................................................................................................
To verify that the pluggable transmission module is properly latched in the cage, gently
pull the pluggable transmission module (parallel to the direction the pluggable
transmission module was installed). Do not rotate the swivel latch or activate the de-
latching feature on the pluggable transmission module.
........................................................................................................................................................................................................................
12
If installing a pluggable transmission module
in an...
Optical OLIU circuit pack,
Ethernet/DATA circuit pack,
........................................................................................................................................................................................................................
13
To test the OC-n optical port on installed OLIU circuit packs, loop back the OC-n optical
port on itself (IN to OUT) with a 15-dB Attenuator.
Result:
........................................................................................................................................................................................................................
14
Remove the lightguide jumper used to loop back the OC-n optical port and the LBO.
Result:
SYSCTL circuit pack.
........................................................................................................................................................................................................................
15
From the System View window, select Configuration
Result:
........................................................................................................................................................................................................................
16
Repeat
........................................................................................................................................................................................................................
17
If installing ethernet pluggable transmission module continue, otherwise proceed to
23
........................................................................................................................................................................................................................
18
To test optical Ethernet ports, with the appropriate fiber type (Single/Multi-Mode) loop
back the optical Ethernet port to itself (In to Out) LBOs are not required with optical
Ethernet ports.
............................................................................................................................................................................................................................................................
G- 1 2
No alarms on the OLIU.
The port LED starts flashing. The
The port LED stops flashing. All alarms are cleared.
Step 1
to
Step 15
for additional pluggable transmission modules.
Install pluggable transmission modules
Then...
Continue with
Step
13.
Proceed to
Step
23.
and
LEDs are lighted on the
MN
NE
Update System
->
Update All.
->
Step
365-372-304R7.1
Issue 2 March 2008

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents