Operational tests
............................................................................................................................................................................................................................................................
........................................................................................................................................................................................................................
14
Unseat the second circuit pack from the same function group pair as the circuit pack
removed in
Result:
........................................................................................................................................................................................................................
15
Press the ACO pushbutton on the SYSCTL.
Result:
The CR audible alarm should clear.
........................................................................................................................................................................................................................
16
Reseat the pair of function units.
........................................................................................................................................................................................................................
17
Turn on the breaker that was turned off in
Result:
........................................................................................................................................................................................................................
18
Disconnect the office alarm cable connected in
procedures in this chapter.
........................................................................................................................................................................................................................
19
Select Configuration -> Alarms -> Alarm Severity Assignment Profile.
........................................................................................................................................................................................................................
20
After screen appears, click the "+" next to ASAP Type System, Highlight DEFAULT and
click the Provision Button.
........................................................................................................................................................................................................................
21
After the screen on the right appears, click on the Alarm Level on the Power/Fuse
Failure row and change the alarm severity Default to Minor.
........................................................................................................................................................................................................................
22
Click APPLY, then Yes.
Note:
............................................................................................................................................................................................................................................................
365-372-304R7.1
Issue 2 March 2008
Step
10.
Activated office alarms: CR visual, CR audible.
Activated office alarm: CR visual.
After a few minutes, all alarm indications should clear.
Do NOT delete the cross-connect that was entered for this test.
Step
12.
Step 1
for the remainder of the test
Office alarm test
5 - 7