Local Equipment And Cross-Connect Tests - Alcatel-Lucent 1665 Installation Manual

Data multiplexer (dmx)
Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Installation tests
............................................................................................................................................................................................................................................................

Local equipment and cross-connect tests

Description
The tests in this section verify the proper operation of the circuit packs and the circuit pack
positions in the Alcatel-Lucent 1665 DMX shelf. It verifies proper cabling from the
Alcatel-Lucent 1665 DMX to the DSX cross-connect panel or connecting equipment. The
shelf must successfully pass this test before testing any other feature of the Alcatel-Lucent
1665 DMX.
It is assumed that
completed and the Alcatel-Lucent 1665 DMX shelf has fiber loop-back cables on the
Main OLIUs with proper LBOs installed, and synchronization set to free-running.
On initial installation/turn-up of Alcatel-Lucent 1665 DMX there are no default cross-
connects. All cross-connects need to be entered for these tests. Upon completion of this
test all cross-connections will be deleted.
Note:
slots and repeat the test. Test all circuit pack positions which have DSX cabling.
Note:
and replace any failed units. If any cabling is corrected or units replaced, repeat the
Local Equipment and cross-connect tests until the units pass without failure.
A properly grounded ESD wrist strap MUST be worn when handling circuit packs.
Unterminated optical connectors may emit laser radiation. Do not view beam with
optical instruments.
DS1 terminating equipment loopback testing
Facility Loopback testing allows the installer to verify electrical cabling to the DS1
Terminating Equipment. This test is only required if the Alcatel-Lucent 1665 DMX shelf
is connected to DS1 terminating equipment such as a DACS. It will be necessary to work
with the Customer Network Control Center to have them establish a terminal loopback. If
the shelf is NOT connected to DS1 terminating equipment, skip this section and continue
with
DS1 non-terminating equipment transmission testing (optical main OLIU) (p.
............................................................................................................................................................................................................................................................
4 - 1 0
Chapter 2, "Powering and initial circuit pack installation"
If the shelf is not fully equipped, move circuit packs to unequipped function
After completing this test, isolate and correct any incorrect wiring or isolate
CAUTION
ESD hazard
WARNING
Laser hazard
Local equipment and cross-connect tests
has been
Issue 2 March 2008
4-12).
365-372-304R7.1