Powering and initial circuit pack installation
............................................................................................................................................................................................................................................................
........................................................................................................................................................................................................................
7
At the Alcatel-Lucent 1665 DMX High-Capacity shelf backplane power connector, use a
voltmeter and measure the voltage on the power cable between BAT A and BAT A RTN.
Then measure the voltage between BAT B and BAT B RTN.
Requirement: The voltage MUST be between -40.00 and -60.0 VDC.
........................................................................................................................................................................................................................
8
Put both circuit breakers on the Alcatel-Lucent 1665 DMX High-Capacity shelf in the
OFF position.
Note:
Alcatel-Lucent 1665 DMX High-Capacity shelf circuit breakers to the OFF position.
........................................................................................................................................................................................................................
9
Reconnect the "A" feed of the power cable to the backplane connector (P14 to J14), and
reconnect the "B" feed of the power cable to the backplane connector (P15 to J15).
........................................................................................................................................................................................................................
10
Place both circuit breakers on the Alcatel-Lucent 1665 DMX High-Capacity shelf in the
ON position.
........................................................................................................................................................................................................................
11
Verify that the fans have started running.
........................................................................................................................................................................................................................
12
At the BDFB/BDCBB either remove the fuse or put the circuit breaker, associated with the
"B" feed of the Alcatel-Lucent 1665 DMX High-Capacity shelf in the OFF position.
........................................................................................................................................................................................................................
13
Verify the PWR A LED on the Alcatel-Lucent 1665 DMX High-Capacity shelf is lighted
with only the "A" feed powered.
............................................................................................................................................................................................................................................................
365-372-304R7.1
Issue 2 March 2008
Designation
BAT A
BAT A RTN
BAT B
BAT B RTN
A small flat-bladed screwdriver or other similar type tool is required to set the
Color
Red
Black/Red
Red
Black/Red
Powering
2 - 5