Operational tests
............................................................................................................................................................................................................................................................
OC-3
LNW82
OC-12
LNW48, LNW50, LNW54, LNW82
OC-48
LNW27, LNW29, LNW32, LNW76, LNW82, LNW202, LNW221-LNW259
OC-192
LNW56, LNW57, LNW58, LNW59 (VLF), LNW60, LNW502, LNW523, LNW527,
LNW554 or LNW555.
It should be noted that switching tests for Function unit circuit packs were performed in
the previous chapter.
........................................................................................................................................................................................................................
1
Establish a CIT session by following the procedure under
(p. 3-9)
........................................................................................................................................................................................................................
2
Select View -> Cross-Connections.
........................................................................................................................................................................................................................
3
Choose shelf (1665 DMX) and click Select.
........................................................................................................................................................................................................................
4
Verify that the cross-connection entered in the previous section is on the list. If the cross
connect exist proceed to
........................................................................................................................................................................................................................
5
Select Configuration -> Cross-Connections.
........................................................................................................................................................................................................................
6
Use the Cross-Connection Wizard to enter a new cross-connection at the STS-1 rate,
UPSR Ring Add/Drop, between m1-1-1 and fn1-1 (fn will be a,b,c or d depending on the
slot where the DS1, DS3, or TMUX CP is located).
This command creates a cross-connection to map 28 DS1s of a DS1 circuit pack or the
first DS3 of a DS3/EC1 or TMUX circuit pack in a Function unit slot(s) to the first STS-1
of the Main OLIUs.
............................................................................................................................................................................................................................................................
5 - 1 0
in
Chapter 3, "Software download and circuit pack
Step 7
Automatic protection switching and alarm test
, otherwise continue to establish a cross connection.
®
Use of WaveStar
CIT software
installation".
365-372-304R7.1