166-808-001 • 166-814-001
166-808-001
IMM I2C Test Aborted
Explanation: Reservation Canceled or Invalid
Reservation ID.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Perform the actions mentioned one at
a time and try the test after each action:
1. Turn off the system and disconnect it from power.
Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the
latest level.
166-809-001
IMM I2C Test Aborted
Explanation: Request data truncated.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Perform the actions mentioned one at
a time and try the test after each action:
1. Turn off the system and disconnect it from power.
Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the
latest level.
166-810-001
IMM I2C Test Aborted
Explanation: Request data length invalid.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Perform the actions mentioned one at
a time and try the test after each action:
1. Turn off the system and disconnect it from power.
Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the
latest level.
166-811-001
IMM I2C Test Aborted
Explanation: Request data field length limit exceeded.
Severity: Warning
Serviceable: Yes
Recoverable: No
366
IBM NeXtScale nx360 M4 Type 5455: Installation and Service Guide
Automatically notify Support: No
User response: Perform the actions mentioned one at
a time and try the test after each action:
1. Turn off the system and disconnect it from power.
Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the
latest level.
166-812-001
IMM I2C Test Aborted
Explanation: Parameter out of range.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Perform the actions mentioned one at
a time and try the test after each action:
1. Turn off the system and disconnect it from power.
Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the
latest level.
166-813-001
IMM I2C Test Aborted
Explanation: Cannot return number of requested data
bytes.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Perform the actions mentioned one at
a time and try the test after each action:
1. Turn off the system and disconnect it from power.
Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the
latest level.
166-814-001
IMM I2C Test Aborted
Explanation: Requested Sensor, data, or record not
present.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Perform the actions mentioned one at
a time and try the test after each action:
1. Turn off the system and disconnect it from power.
Wait for 45 seconds. Reconnect it to power.