IBM NeXtScale nx360 M4 Installation And Service Manual page 239

Hide thumbs Also See for NeXtScale nx360 M4:
Table of Contents

Advertisement

Alert Category: Critical - Voltage
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 1
Automatically notify Support: No
User response:
1.
Check the system-event log.
2.
Check for an error LED on the system board.
3.
Replace any failing device.
4.
Check for a server firmware update. Important:
Some cluster solutions require specific code levels
or coordinated code updates. If the device is part of
a cluster solution, verify that the latest level of code
is supported for the cluster solution before you
update the code.
5.
(Trained technician only) Replace the system board.
80070202-1501ffff
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (PIB Fault)
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
Severity: Error
Alert Category: Critical - Voltage
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 1
Automatically notify Support: No
User response: Replace node.
80070202-1502ffff
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (PDB Fault)
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
Severity: Error
Alert Category: Critical - Voltage
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 1
Automatically notify Support: No
User response:
1.
Check the system-event log.
2.
Check for an error LED on the system board.
80070202-1501ffff • 8007020f-2582ffff
3.
Replace any failing device.
4.
Check for a server firmware update. Important:
Some cluster solutions require specific code levels
or coordinated code updates. If the device is part of
a cluster solution, verify that the latest level of code
is supported for the cluster solution before you
update the code.
5.
(Trained technician only) Replace the system board.
8007020f-2201ffff
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
If enabling TXT is not required, disable TXT from
the Setup Utility.
2.
If enabling TXT is required, verify that the TPM is
enabled and activated from the Setup Utility.
3.
If the problem remains, contact your service
representative.
8007020f-2582ffff
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 50
Automatically notify Support: No
User response: Complete the following step to solve
PCI I/O resource errors:
1.
Go to F1 Setup
2.
System Settings
3.
Device and I/O ports
4.
PCI 64 bit Resource and choose enable
Appendix A. Integrated Management Module II (IMM2) error messages
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (TXT ACM Module)
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (I/O Resources)
221

Advertisement

Table of Contents
loading

Table of Contents