IBM NeXtScale nx360 M4 Installation And Service Manual page 259

Hide thumbs Also See for NeXtScale nx360 M4:
Table of Contents

Advertisement

806f020d-0402ffff
Failure Predicted on drive
[StorageVolumeElementName] for array
[ComputerSystemElementName].
(Computer HDD1)
Explanation: This message is for the use case when an
implementation has detected an Array Failure is
Predicted.
Severity: Warning
Alert Category: System - Predicted Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0168
SNMP Trap ID: 27
Automatically notify Support: Yes
User response:
1.
Run the hard disk drive diagnostic test on drive n.
2.
Reseat the following components: a. Hard disk
drive b. Cable from the system board to the
backplane.
3.
Replace the following components one at a time, in
the order shown, restarting the server each time: a.
Hard disk drive. b. Cable from the system board to
the backplane. c. Hard disk drive backplane. (n =
hard disk drive number)
806f020d-0403ffff
Failure Predicted on drive
[StorageVolumeElementName] for array
[ComputerSystemElementName].
(Computer HDD2)
Explanation: This message is for the use case when an
implementation has detected an Array Failure is
Predicted.
Severity: Warning
Alert Category: System - Predicted Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0168
SNMP Trap ID: 27
Automatically notify Support: Yes
User response:
1.
Run the hard disk drive diagnostic test on drive n.
2.
Reseat the following components: a. Hard disk
drive b. Cable from the system board to the
backplane.
3.
Replace the following components one at a time, in
the order shown, restarting the server each time: a.
Hard disk drive. b. Cable from the system board to
the backplane. c. Hard disk drive backplane. (n =
hard disk drive number)
806f020d-0402ffff • 806f020d-0405ffff
806f020d-0404ffff
Explanation: This message is for the use case when an
implementation has detected an Array Failure is
Predicted.
Severity: Warning
Alert Category: System - Predicted Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0168
SNMP Trap ID: 27
Automatically notify Support: Yes
User response:
1.
Run the hard disk drive diagnostic test on drive n.
2.
Reseat the following components: a. Hard disk
drive b. Cable from the system board to the
backplane.
3.
Replace the following components one at a time, in
the order shown, restarting the server each time: a.
Hard disk drive. b. Cable from the system board to
the backplane. c. Hard disk drive backplane. (n =
hard disk drive number)
806f020d-0405ffff
Explanation: This message is for the use case when an
implementation has detected an Array Failure is
Predicted.
Severity: Warning
Alert Category: System - Predicted Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0168
SNMP Trap ID: 27
Automatically notify Support: Yes
User response:
1.
Run the hard disk drive diagnostic test on drive n.
2.
Reseat the following components: a. Hard disk
drive b. Cable from the system board to the
backplane.
3.
Replace the following components one at a time, in
the order shown, restarting the server each time: a.
Hard disk drive. b. Cable from the system board to
the backplane. c. Hard disk drive backplane. (n =
hard disk drive number)
Appendix A. Integrated Management Module II (IMM2) error messages
Failure Predicted on drive
[StorageVolumeElementName] for array
[ComputerSystemElementName].
(Computer HDD3)
Failure Predicted on drive
[StorageVolumeElementName] for array
[ComputerSystemElementName]. (1U
Storage HDD0)
241

Advertisement

Table of Contents
loading