IBM NeXtScale nx360 M4 Installation And Service Manual page 330

Hide thumbs Also See for NeXtScale nx360 M4:
Table of Contents

Advertisement

I.2018002 • I.3818002
1.
Verify that matching Processors are installed in the
correct Processor sockets according to the service
information for this product.
2.
Check IBM support site for an applicable service
bulletin or firmware update that applies to this
Processor error.
3.
(Trained Service technician only) Replace the
system board.
I.2018002
[I.2018002] The device found at Bus %
Device % Function % could not be
configured due to resource constraints.
The Vendor ID for the device is % and
the Device ID is %.
Explanation: OUT_OF_RESOURCES (PCI Option
ROM)
Severity: Info
User response: Complete the following steps:
1.
If this PCIe device and/or any attached cables
were recently installed, moved, serviced or
upgraded, reseat adapter and any attached cables.
2.
Check IBM support site for any applicable service
bulletin or UEFI or adapter firmware update that
applies to this error. NOTE: It may be necessary to
disable unused option ROMs from UEFI F1 setup or
ASU or using adapter manufacturer utilities so that
adapter firmware can be updated.
3.
Move card to a different slot. If slot not available or
error re-occurs, replace adapter.
4.
(Trained Service technician only) If adapter was
moved to a different slot and error did not re-occur,
verify that this is not a system limitation and then
replace the system board. Also, if this is not the
initial installation and the error persists after
adapter replacement, replace system board.
I.2018003
[I.2018003] A bad option ROM
checksum was detected for the device
found at Bus % Device % Function %.
The Vendor ID for the device is % and
the Device ID is %.
Explanation: ROM CHECKSUM ERROR
Severity: Error
User response: Complete the following steps:
1.
If this PCIe device and/or any attached cables
were recently installed, moved, serviced or
upgraded, reseat adapter and any attached cables.
2.
Move adapter to a different system slot, if
available.
3.
Check IBM support site for any applicable service
bulletin or UEFI or adapter firmware update that
applies to this error. NOTE: It may be necessary to
configure slot to Gen1 or to use special utility
software so that adapter firmware can be upgraded.
312
IBM NeXtScale nx360 M4 Type 5455: Installation and Service Guide
Gen1/Gen2 settings can be configured via F1 Setup
-> System Settings -> Devices and I/O Ports ->
PCIe Gen1/Gen2/Gen3 Speed Selection, or the ASU
Utility.
4.
Replace adapter.
I.3048005
[I.3048005] UEFI has booted from the
backup flash bank.
Explanation: Booting Backup UEFI Image
Severity: Info
User response: Complete the following steps:
1.
Refer to service information for this product section
on UEFI Recovery to return system to primary
bank.
I.3808004
[I.3808004] The IMM System Event log
(SEL) is full.
Explanation: IPMI System Event Log is Full
Severity: Info
User response: Complete the following steps:
1.
Use IMM Web Interface to clear event log.
2.
If IMM communication is unavailable, use F1 Setup
to access System Event Logs Menu and Choose
Clear IMM System Event Log and Restart Server.
I.3818001
[I.3818001] The firmware image capsule
signature for the currently booted flash
bank is invalid.
Explanation: Current Bank CRTM Capsule Update
Signature Invalid
Severity: Info
User response: Complete the following steps:
1.
Reboot system. Will come up on backup UEFI
image. Reflash the primary UEFI image.
2.
If error does not persist no additional recovery
action is required.
3.
If error persists, or boot is unsuccessful, (Trained
service technician only) Replace the system board.
I.3818002
[I.3818002] The firmware image capsule
signature for the non-booted flash bank
is invalid.
Explanation: Opposite Bank CRTM Capsule Update
Signature Invalid
Severity: Info
User response: Complete the following steps:
1.
Reflash backup UEFI image.
2.
If error does not persist no additional recovery
action is required.

Advertisement