implementation has detected Memory has been
Throttled.
Severity: Warning
Alert Category: System - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0142
SNMP Trap ID: 22
Automatically notify Support: No
User response:
1.
Reseat the DIMM, and then restart the server.
2.
Replace DIMM n. (n = DIMM number)
806f0a07-0301ffff
[ProcessorElementName] is
operating in a Degraded State. (CPU 1)
Explanation: This message is for the use case when an
implementation has detected a Processor is running in
the Degraded state.
Severity: Warning
Alert Category: Warning - CPU
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0038
SNMP Trap ID: 42
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating, that there
are no obstructions to the airflow (front and rear of
the server), that the air baffles are in place and
correctly installed, and that the server cover is
installed and completely closed.
2.
Check the ambient temperature. You must be
operating within the specifications.
3.
Make sure that the heat sink for microprocessor n
is installed correctly.
4.
(Trained technician only) Replace microprocessor n.
(n = microprocessor number)
806f0a07-0302ffff
[ProcessorElementName] is
operating in a Degraded State. (CPU 2)
Explanation: This message is for the use case when an
implementation has detected a Processor is running in
the Degraded state.
Severity: Warning
Alert Category: Warning - CPU
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0038
SNMP Trap ID: 42
806f0a07-0301ffff • 806f0a0c-2002ffff
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating, that there
are no obstructions to the airflow (front and rear of
the server), that the air baffles are in place and
correctly installed, and that the server cover is
installed and completely closed.
2.
Check the ambient temperature. You must be
operating within the specifications.
3.
Make sure that the heat sink for microprocessor n
is installed correctly.
4.
(Trained technician only) Replace microprocessor n.
(n = microprocessor number)
806f0a0c-2001ffff
Explanation: This message is for the use case when an
implementation has detected an Over Temperature
Condition for Memory that has been Detected.
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0146
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating, that there
are no obstructions to the airflow, that the air baffles
are in place and correctly installed, and that the
server cover is installed and completely closed.
2.
Make sure that ambient temperature is within the
specifications.
3.
If a fan has failed, complete the action for a fan
failure.
4.
Replace DIMM n. (n = DIMM number)
806f0a0c-2002ffff
Explanation: This message is for the use case when an
implementation has detected an Over Temperature
Condition for Memory that has been Detected.
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
Appendix A. Integrated Management Module II (IMM2) error messages
An Over-Temperature Condition
has been detected on the
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 1)
An Over-Temperature Condition
has been detected on the
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 2)
267