80010b01-0701ffff
Numeric sensor
[NumericSensorElementName] going
high (upper non-recoverable) has
asserted. (Ambient Temp)
Explanation: This message is for the use case when an
implementation has detected an Upper Non-recoverable
sensor going high has asserted.
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0498
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure there is a node filler correctly installed
for the empty node slot.
2.
Make sure the air baffles are placed and correctly
installed; and make sure the node cover is installed
and completely closed.
3.
Make sure the fans are operating, and there are no
obstructions to the airflow (both front and rear of
the server).
4.
Reduce the Ambient temperature. The system must
be operating within the specifications. (see Features
and specifications for more information)
80010b01-0702ffff
Numeric sensor
[NumericSensorElementName] going
high (upper non-recoverable) has
asserted. (DIMM AB Temp)
Explanation: This message is for the use case when an
implementation has detected an Upper Non-recoverable
sensor going high has asserted.
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0498
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure there is a node filler correctly installed
for the empty node slot.
2.
Make sure the air baffles are placed and correctly
installed; and make sure the node cover is installed
and completely closed.
3.
Make sure the fans are operating, and there are no
obstructions to the airflow (both front and rear of
the server).
80010b01-0701ffff • 80010b01-0704ffff
4.
Reduce the Ambient temperature. The system must
be operating within the specifications. (see Features
and specifications for more information)
80010b01-0703ffff
Explanation: This message is for the use case when an
implementation has detected an Upper Non-recoverable
sensor going high has asserted.
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0498
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure there is a node filler correctly installed
for the empty node slot.
2.
Make sure the air baffles are placed and correctly
installed; and make sure the node cover is installed
and completely closed.
3.
Make sure the fans are operating, and there are no
obstructions to the airflow (both front and rear of
the server).
4.
Reduce the Ambient temperature. The system must
be operating within the specifications. (see Features
and specifications for more information)
80010b01-0704ffff
Explanation: This message is for the use case when an
implementation has detected an Upper Non-recoverable
sensor going high has asserted.
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0498
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure there is a node filler correctly installed
for the empty node slot.
2.
Make sure the air baffles are placed and correctly
installed; and make sure the node cover is installed
and completely closed.
Appendix A. Integrated Management Module II (IMM2) error messages
Numeric sensor
[NumericSensorElementName] going
high (upper non-recoverable) has
asserted. (CPU1 VR Temp VCO)
Numeric sensor
[NumericSensorElementName] going
high (upper non-recoverable) has
asserted. (HDD Inlet Temp)