IBM NeXtScale nx360 M4 Installation And Service Manual page 277

Hide thumbs Also See for NeXtScale nx360 M4:
Table of Contents

Advertisement

SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Replace the RAID adapter.
5.
Replace the hard disk drive that is indicated by a
lit status LED.
806f060d-0407ffff
Array
[ComputerSystemElementName] has
failed. (1U Storage HDD2)
Explanation: This message is for the use case when an
implementation has detected that an Array Failed.
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Replace the RAID adapter.
5.
Replace the hard disk drive that is indicated by a
lit status LED.
806f060d-0408ffff
Array
[ComputerSystemElementName] has
failed. (1U Storage HDD3)
Explanation: This message is for the use case when an
implementation has detected that an Array Failed.
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
806f060d-0407ffff • 806f060d-040affff
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Replace the RAID adapter.
5.
Replace the hard disk drive that is indicated by a
lit status LED.
806f060d-0409ffff
Explanation: This message is for the use case when an
implementation has detected that an Array Failed.
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Replace the RAID adapter.
5.
Replace the hard disk drive that is indicated by a
lit status LED.
806f060d-040affff
Explanation: This message is for the use case when an
implementation has detected that an Array Failed.
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Replace the RAID adapter.
5.
Replace the hard disk drive that is indicated by a
lit status LED.
Appendix A. Integrated Management Module II (IMM2) error messages
Array
[ComputerSystemElementName] has
failed. (1U Storage HDD4)
Array
[ComputerSystemElementName] has
failed. (1U Storage HDD5)
259

Advertisement

Table of Contents
loading

Table of Contents