IBM NeXtScale nx360 M4 Installation And Service Manual page 272

Hide thumbs Also See for NeXtScale nx360 M4:
Table of Contents

Advertisement

806f050d-0403ffff • 806f050d-0406ffff
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Check backplane cable connection.
5.
Replace the RAID adapter.
6.
Replace the hard disk drive that is indicated by a
lit status LED.
806f050d-0403ffff
Array
[ComputerSystemElementName] is in
critical condition. (Computer HDD2)
Explanation: This message is for the use case when an
implementation has detected that an Array is Critical.
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Check backplane cable connection.
5.
Replace the RAID adapter.
6.
Replace the hard disk drive that is indicated by a
lit status LED.
806f050d-0404ffff
Array
[ComputerSystemElementName] is in
critical condition. (Computer HDD3)
Explanation: This message is for the use case when an
implementation has detected that an Array is Critical.
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
254
IBM NeXtScale nx360 M4 Type 5455: Installation and Service Guide
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Check backplane cable connection.
5.
Replace the RAID adapter.
6.
Replace the hard disk drive that is indicated by a
lit status LED.
806f050d-0405ffff
Array
[ComputerSystemElementName] is in
critical condition. (1U Storage HDD0)
Explanation: This message is for the use case when an
implementation has detected that an Array is Critical.
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Check backplane cable connection.
5.
Replace the RAID adapter.
6.
Replace the hard disk drive that is indicated by a
lit status LED.
806f050d-0406ffff
Array
[ComputerSystemElementName] is in
critical condition. (1U Storage HDD1)
Explanation: This message is for the use case when an
implementation has detected that an Array is Critical.
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.

Advertisement

Table of Contents
loading