SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
806f0028-2101ffff
Sensor [SensorElementName] is
unavailable or degraded on management
system [ComputerSystemElementName].
(TPM Cmd Failures)
Explanation: This message is for the use case when an
implementation has detected a Sensor is Unavailable or
degraded.
Severity: Warning
Alert Category: Warning - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0398
SNMP Trap ID: 60
Automatically notify Support: No
User response:
1.
Turn off the server and disconnect the power cords.
Reconnect the power cords and restart the server.
2.
If the problem remains, (trained technician only)
replace the system board.
806f0107-0301ffff
An Over-Temperature Condition
has been detected on
[ProcessorElementName]. (CPU 1)
Explanation: This message is for the use case when an
implementation has detected an Over-Temperature
Condition Detected for Processor.
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0036
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating. There are no
obstructions to the airflow (front and rear of the
server), the air baffles are in place and correctly
installed, and the server cover is installed and
completely closed.
2.
Make sure that the heat sink for microprocessor n
is installed correctly.
3.
(Trained technician only) Replace microprocessor n.
(n = microprocessor number)
806f0028-2101ffff • 806f010c-2001ffff
806f0107-0302ffff
Explanation: This message is for the use case when an
implementation has detected an Over-Temperature
Condition Detected for Processor.
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0036
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating. There are no
obstructions to the airflow (front and rear of the
server), the air baffles are in place and correctly
installed, and the server cover is installed and
completely closed.
2.
Make sure that the heat sink for microprocessor n
is installed correctly.
3.
(Trained technician only) Replace microprocessor n.
(n = microprocessor number)
806f0109-1301ffff
Explanation: This message is for the use case when an
implementation has detected a Power Unit that has
been power cycled.
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0108
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
806f010c-2001ffff
Explanation: This message is for the use case when an
implementation has detected a Memory uncorrectable
error.
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0138
Appendix A. Integrated Management Module II (IMM2) error messages
An Over-Temperature Condition
has been detected on
[ProcessorElementName]. (CPU 2)
[PowerSupplyElementName] has
been Power Cycled. (Host Power)
Uncorrectable error detected for
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 1)
231