Figure 83. Front PCI riser-cage assembly installation
Rear PCI riser
assembly
Figure 84. Rear PCI riser-cage assembly installation
10. Replace the cover (see "Installing the compute node cover" on page 111).
11. Slide the server into the rack.
12. Reconnect the power cords and any cables that you removed.
13. Turn on the peripheral devices and the server.
158
IBM NeXtScale nx360 M4 Type 5455: Installation and Service Guide
2. Turn off the server and peripheral devices and disconnect all power cords.
3. Remove the cover (see "Removing the compute node cover" on page 110).
4. Install the GPU adapter in the new PCI riser-cage assembly (see "Replacing an
adapter/GPU adapter" on page 160).
5. Remove the PCI filler panel, if one is present, from the server.
6. Align the PCI riser-cage assembly with the PCI riser connector on the system
board; then, grasp the rear side of the PCI riser-cage touch point and the front
PCI rise- cage suitable location of the PCI riser-cage assembly.
7. Press down firmly until the PCI riser-cage assembly is seated correctly in the
connector on the system board.
Front PCI riser
assembly
8. Re-install the GPU tray into the compute node (see "Installing a GPU tray into
a compute node" on page 109).
9. Reinstall the air baffle (see "Replacing the air baffle" on page 114) if you are
installing the rear PCI-riser cage assembly.
Guide pin
Guide pins