IBM NeXtScale nx360 M4 Installation And Service Manual page 257

Hide thumbs Also See for NeXtScale nx360 M4:
Table of Contents

Advertisement

806f0123-2101ffff
Reboot of system
[ComputerSystemElementName]
initiated by [WatchdogElementName].
(IPMI Watchdog)
Explanation: This message is for the use case when an
implementation has detected a Reboot by a Watchdog
occurred.
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0370
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
806f0125-1001ffff
[ManagedElementName] detected
as absent. (PCI Riser 1)
Explanation: This message is for the use case when an
implementation has detected a Managed Element is
Absent.
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0392
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
806f0125-1002ffff
[ManagedElementName] detected
as absent. (PCI Riser 2)
Explanation: This message is for the use case when an
implementation has detected a Managed Element is
Absent.
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0392
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
806f0123-2101ffff • 806f0207-0301ffff
806f0125-1f01ffff
Explanation: This message is for the use case when an
implementation has detected a Managed Element is
Absent.
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0392
SNMP Trap ID:
Automatically notify Support: No
User response: If there is no GPU/storage tray
installed in the system, then the log event is a normal
condition. If there is a GPU/storage tray installed in
the system, then check the following two portions:
1.
PDB (Power Distribution Board) cable is correctly
connected from riser card to PDB.
2.
Replace another PDB cable.
806f0125-2c01ffff
Explanation: This message is for the use case when an
implementation has detected a Managed Element is
Absent.
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0392
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
806f0207-0301ffff
Explanation: This message is for the use case when an
implementation has detected a Processor Failed -
FRB1/BIST condition.
Severity: Error
Alert Category: Critical - CPU
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0044
SNMP Trap ID: 40
Automatically notify Support: Yes
User response:
Appendix A. Integrated Management Module II (IMM2) error messages
[ManagedElementName] detected
as absent. (PDB Cable)
[ManagedElementName] detected
as absent. (Mezz Card)
[ProcessorElementName] has
Failed with FRB1/BIST condition. (CPU
1)
239

Advertisement

Table of Contents
loading