405-801-000 • 405-901-000
405-801-000
BRCM:TestMIIRegisters Test Aborted
Explanation: The MII register test was canceled.
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
405-802-000
BRCM:TestEEPROM Test Aborted
Explanation: The EEPROM test was canceled.
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
405-803-000
BRCM:TestInternalMemory Test
Aborted
Explanation: The internal memory test was canceled.
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
405-804-000
BRCM:TestInterrupt Test Aborted
Explanation: The interrupt test was canceled.
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
405-805-000
BRCM:TestLoopbackMAC Test Aborted
Explanation: Loopback testing at the MAC layer was
canceled.
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
405-806-000
BRCM:TestLoopbackPhysical Test
Aborted
Explanation: Loopback testing at the physical layer
was canceled.
Severity: Warning
Serviceable: No
322
IBM NeXtScale nx360 M4 Type 5455: Installation and Service Guide
Recoverable: No
Automatically notify Support: No
405-807-000
BRCM:TestLEDs Test Aborted
Explanation: Verification of status LEDs was canceled.
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
405-900-000
BRCM:TestControlRegisters Test Failed
Explanation: A failure was detected while testing
internal MAC registers
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check component firmware level and upgrade if
necessary. The installed firmware level can be found
in the DSA Diagnostic Event Log within the
Firmware/VPD section for this component.
2. Rerun the test.
3. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
405-901-000
BRCM:TestMIIRegisters Test Failed
Explanation: A failure was detected while testing
internal PHY registers.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check component firmware level and upgrade if
necessary. The installed firmware level can be found
in the DSA Diagnostic Event Log within the
Firmware/VPD section for this component.
2. Rerun the test.
3. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.