User response: No action; information only.
816f0a0c-2006ffff
An Over-Temperature Condition
has been removed on the
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 6)
Explanation: This message is for the use case when an
implementation has detected an Over Temperature
Condition for Memory that has been Removed.
Severity: Info
Alert Category: Critical - Temperature
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0147
SNMP Trap ID: 0
Automatically notify Support: No
User response: No action; information only.
816f0a0c-2007ffff
An Over-Temperature Condition
has been removed on the
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 7)
Explanation: This message is for the use case when an
implementation has detected an Over Temperature
Condition for Memory that has been Removed.
Severity: Info
Alert Category: Critical - Temperature
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0147
SNMP Trap ID: 0
Automatically notify Support: No
User response: No action; information only.
816f0a0c-2008ffff
An Over-Temperature Condition
has been removed on the
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 8)
Explanation: This message is for the use case when an
implementation has detected an Over Temperature
Condition for Memory that has been Removed.
Severity: Info
Alert Category: Critical - Temperature
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0147
SNMP Trap ID: 0
816f0a0c-2006ffff • 816f0a13-0302ffff
Automatically notify Support: No
User response: No action; information only.
816f0a13-0301ffff
Explanation: This message is for the use case when an
implementation has detected that a system has
recovered from a Bus Fatal Error.
Severity: Info
Alert Category: Critical - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0245
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
(Trained technician only) Replace microprocessor n
(see Removing a microprocessor and heat sink and
Replacing a microprocessor and heat sink).
2.
If the problem persists and there is no other CPU
with the same error indication, replace the system
board.
3.
(Trained technician only) Replace the system board
(see Removing the system board and Installing the
system board). (n = microprocessor number)
816f0a13-0302ffff
Explanation: This message is for the use case when an
implementation has detected that a system has
recovered from a Bus Fatal Error.
Severity: Info
Alert Category: Critical - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0245
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
(Trained technician only) Replace microprocessor n
(see Removing a microprocessor and heat sink and
Replacing a microprocessor and heat sink).
2.
If the problem persists and there is no other CPU
with the same error indication, replace the system
board.
Appendix A. Integrated Management Module II (IMM2) error messages
System
[ComputerSystemElementName] has
recovered from a Fatal Bus Error. (CPU 1
PECI)
System
[ComputerSystemElementName] has
recovered from a Fatal Bus Error. (CPU 2
PECI)
307