CIM Information: Prefix: PLAT and ID: 0494
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure there is a node filler correctly installed
for the empty node slot.
2.
Make sure the air baffles are placed and correctly
installed; and make sure the node cover is installed
and completely closed.
3.
Make sure the fans are operating, and there are no
obstructions to the airflow (both front and rear of
the server).
4.
Reduce the Ambient temperature. The system must
be operating within the specifications. (see Features
and specifications for more information)
80010901-1002ffff
Numeric sensor
[NumericSensorElementName] going
high (upper critical) has asserted. (PCI
Riser 2 Temp)
Explanation: This message is for the use case when an
implementation has detected an Upper Critical sensor
going high has asserted.
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0494
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure there is a node filler correctly installed
for the empty node slot.
2.
Make sure the air baffles are placed and correctly
installed; and make sure the node cover is installed
and completely closed.
3.
Make sure the fans are operating, and there are no
obstructions to the airflow (both front and rear of
the server).
4.
Reduce the Ambient temperature. The system must
be operating within the specifications. (see Features
and specifications for more information)
80010901-1501ffff
Numeric sensor
[NumericSensorElementName] going
high (upper critical) has asserted. (PIB
Ambient Temp)
Explanation: This message is for the use case when an
implementation has detected an Upper Critical sensor
going high has asserted.
Severity: Error
80010901-1002ffff • 80010901-1a01ffff
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0494
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure there is a node filler correctly installed
for the empty node slot.
2.
Make sure the air baffles are placed and correctly
installed; and make sure the node cover is installed
and completely closed.
3.
Make sure the fans are operating, and there are no
obstructions to the airflow (both front and rear of
the server).
4.
Reduce the Ambient temperature. The system must
be operating within the specifications. (see Features
and specifications for more information)
80010901-1502ffff
Explanation: This message is for the use case when an
implementation has detected an Upper Critical sensor
going high has asserted.
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0494
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure there is a node filler correctly installed
for the empty node slot.
2.
Make sure the air baffles are placed and correctly
installed; and make sure the node cover is installed
and completely closed.
3.
Make sure the fans are operating, and there are no
obstructions to the airflow (both front and rear of
the server).
4.
Reduce the Ambient temperature. The system must
be operating within the specifications. (see Features
and specifications for more information)
80010901-1a01ffff
Explanation: This message is for the use case when an
Appendix A. Integrated Management Module II (IMM2) error messages
Numeric sensor
[NumericSensorElementName] going
high (upper critical) has asserted. (GPU
Outlet Temp)
Numeric sensor
[NumericSensorElementName] going
high (upper critical) has asserted. (HDD
Outlet Temp)