IBM NeXtScale nx360 M4 Installation And Service Manual page 237

Hide thumbs Also See for NeXtScale nx360 M4:
Table of Contents

Advertisement

Alert Category: Warning - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0520
SNMP Trap ID: 60
Automatically notify Support: No
User response:
1.
Restart IMM. If the error doesn't disappear, please
proceed step 2.
2.
Update to the latest level of iMM/uEFI code,
please proceed step 3.
3.
Replace node.
80070201-0301ffff
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (CPU 1 OverTemp)
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure there is a node filler correctly installed
for the empty node slot.
2.
Make sure the air baffles are placed and correctly
installed; and make sure the node cover is installed
and completely closed.
3.
Make sure the fans are operating, and there are no
obstructions to the airflow (both front and rear of
the server).
4.
Reduce the Ambient temperature. The system must
be operating within the specifications. (see Features
and specifications for more information)
5.
Make sure the PCI adapter is supported by the
server. To confirm, see the IBM ServerProven
website.
6.
Replace the PCI adapter and make sure the PCI
adapter is functioning normally.
80070201-0302ffff
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (CPU 2 OverTemp)
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
Severity: Error
80070201-0301ffff • 80070201-1101ffff
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure there is a node filler correctly installed
for the empty node slot.
2.
Make sure the air baffles are placed and correctly
installed; and make sure the node cover is installed
and completely closed.
3.
Make sure the fans are operating, and there are no
obstructions to the airflow (both front and rear of
the server).
4.
Reduce the Ambient temperature. The system must
be operating within the specifications. (see Features
and specifications for more information)
5.
Make sure the PCI adapter is supported by the
server. To confirm, see the IBM ServerProven
website.
6.
Replace the PCI adapter and make sure the PCI
adapter is functioning normally.
80070201-1101ffff
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure there is a node filler correctly installed
for the empty node slot.
2.
Make sure the air baffles are placed and correctly
installed; and make sure the node cover is installed
and completely closed.
3.
Make sure the fans are operating, and there are no
obstructions to the airflow (both front and rear of
the server).
4.
Reduce the Ambient temperature. The system must
be operating within the specifications. (see Features
and specifications for more information)
5.
Make sure the PCI adapter is supported by the
server. To confirm, see the IBM ServerProven
website.
Appendix A. Integrated Management Module II (IMM2) error messages
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (PCI 1 Temp)
219

Advertisement

Table of Contents
loading

Table of Contents