806f0a0c-2003ffff • 806f0a0c-2006ffff
CIM Information: Prefix: PLAT and ID: 0146
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating, that there
are no obstructions to the airflow, that the air baffles
are in place and correctly installed, and that the
server cover is installed and completely closed.
2.
Make sure that ambient temperature is within the
specifications.
3.
If a fan has failed, complete the action for a fan
failure.
4.
Replace DIMM n. (n = DIMM number)
806f0a0c-2003ffff
An Over-Temperature Condition
has been detected on the
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 3)
Explanation: This message is for the use case when an
implementation has detected an Over Temperature
Condition for Memory that has been Detected.
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0146
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating, that there
are no obstructions to the airflow, that the air baffles
are in place and correctly installed, and that the
server cover is installed and completely closed.
2.
Make sure that ambient temperature is within the
specifications.
3.
If a fan has failed, complete the action for a fan
failure.
4.
Replace DIMM n. (n = DIMM number)
806f0a0c-2004ffff
An Over-Temperature Condition
has been detected on the
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 4)
Explanation: This message is for the use case when an
implementation has detected an Over Temperature
Condition for Memory that has been Detected.
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
268
IBM NeXtScale nx360 M4 Type 5455: Installation and Service Guide
CIM Information: Prefix: PLAT and ID: 0146
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating, that there
are no obstructions to the airflow, that the air baffles
are in place and correctly installed, and that the
server cover is installed and completely closed.
2.
Make sure that ambient temperature is within the
specifications.
3.
If a fan has failed, complete the action for a fan
failure.
4.
Replace DIMM n. (n = DIMM number)
806f0a0c-2005ffff
An Over-Temperature Condition
has been detected on the
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 5)
Explanation: This message is for the use case when an
implementation has detected an Over Temperature
Condition for Memory that has been Detected.
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0146
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating, that there
are no obstructions to the airflow, that the air baffles
are in place and correctly installed, and that the
server cover is installed and completely closed.
2.
Make sure that ambient temperature is within the
specifications.
3.
If a fan has failed, complete the action for a fan
failure.
4.
Replace DIMM n. (n = DIMM number)
806f0a0c-2006ffff
An Over-Temperature Condition
has been detected on the
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 6)
Explanation: This message is for the use case when an
implementation has detected an Over Temperature
Condition for Memory that has been Detected.
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes