Fault Finding (Air Conditioning); No Air Conditioning - jcb 214e Service Manual

Backhoe loader
Hide thumbs Also See for 214e:
Table of Contents

Advertisement

www.WorkshopManuals.co.uk
Section B
10 - 2
Air Conditioning (cont'd)

No Air Conditioning

CHECK
1
Are the controls set correctly, i.e. air conditioning
selected, thermostat switch set to coldest position
and blower switched on?
2
Is the air conditioning (evaporator) blower working?
3
Is the compressor running (visual check of pulley/clutch)?
4
Is the air conditioning fuse(s) blown?
5
Is there a 12V supply to the pressure switch harness?
Refer to Service Procedures - Pressure Switch Testing
6
Does the compressor clutch engage with
pressure switch assembly bypassed?
Refer to Service Procedures - Pressure Switch Testing
7
Does the clutch engage with thermostat switch
bypassed?
8
Are blower switch and wiring OK?
9
Is sight glass indication OK?
10 Is condensor air flow blocked?
11 Is evaporator air flow blocked?
9803/3280
Body & Framework
Fault Finding
Purchased from www.WorkshopManuals.co.uk
ACTION
YES:
Check 2
NO:
Reset controls and retest.
YES:
Check 3.
NO:
Check 4.
YES:
Check 9.
NO:
Check 5.
YES:
Renew fuse(s) and retest.
NO:
Check 8.
YES:
Check 6.
NO:
Check 7.
YES:
Replace pressure switch assembly.
NO:
Renew the compressor clutch and retest.
YES:
Renew thermostat switch and retest.
NO:
Check all electrical connections.
YES:
Renew blower unit complete.
NO:
Renew switch or wiring.
YES:
Check 10.
NO:
Charge check required by refrigeration engineer or
suitably trained person.
YES:
Clean condensor and radiator.
NO:
Check 11.
YES:
Clean filter and, if necessary the evaporator.
NO:
Call in refrigeration engineer or suitably trained
person.
Section B
10 - 2
Issue 1

Advertisement

Table of Contents
loading

This manual is also suitable for:

4cx3cx214215217

Table of Contents