Low R-134A Charge; Poor Refrigerant Circulation; System Diagnosis - jcb 214e Service Manual

Backhoe loader
Hide thumbs Also See for 214e:
Table of Contents

Advertisement

www.WorkshopManuals.co.uk
Section B
10 - 4
Air Conditioning
- System Diagnosis (cont'd)

Low R-134a Charge

Gauge Readings:
Low Side Gauge - Low.
High Side Gauge - Low.
Other symptoms:
Sight Glass - Bubbles continuously visible.
Diagnosis:
System slightly low on R- 134a, due to leak or
incorrect charge.
Correction:
1. Leak test system.
2. Evacuate A/C system.
3. Repair system leaks.
4. Charge system with R-134a.
5. Operate system and check performance.

Poor Refrigerant Circulation

Gauge Readings:
Low Side Gauge - Zero to negative.
High Side Gauge - Low.
Other symptoms:
Receiver-Drier - Frost on tubes from receiver-drier
to evaporator unit.
Diagnosis:
Refrigerant flow obstructed by dirt, receiver-drier
clogged.
Correction:
1. Evacuate A/C system.
2. Replace receiver-drier.
3. Charge system with R-134a.
4. Operate system and check performance.
9803/3280
Body & Framework
Fault Finding
Purchased from www.WorkshopManuals.co.uk
LOW SIDE (Blue)
Low
LOW SIDE - 0.76 bar (0.77 kgf/cm
HIGH SIDE - 8.3 bar (8.5 kgf/cm
LOW SIDE (Blue)
Zero to negative
LOW SIDE - -1.0 bar (-1.1 kgf/cm
HIGH SIDE - 5.4 bar (5.5 kgf/cm
Section B
10 - 4
HIGH SIDE (Red)
Low
A268030
2
)(11 lbf/in
2
)
2
)(121 lbf/in
2
)
HIGH SIDE (Red)
Low
A268040
2
)(-15 lbf/in
2
)
2
)(78 lbf/in
2
)
Issue 1

Advertisement

Table of Contents
loading

This manual is also suitable for:

4cx3cx214215217

Table of Contents