Compressor Malfunction; Some Moisture In The System - jcb 214e Service Manual

Backhoe loader
Hide thumbs Also See for 214e:
Table of Contents

Advertisement

www.WorkshopManuals.co.uk
Section B
10 - 7
Air Conditioning
- System Diagnosis (cont'd)

Compressor Malfunction

Gauge Readings:
Low Side Gauge - High.
High Side Gauge - Low.
Diagnosis:
Internal
compressor
mechanically broken.
Correction:
1. Evacuate A/C system.
2. Repair or replace compressor.
3. Charge system with R-134a.
4. Operate system and check performance.

Some Moisture in the System

Gauge Readings:
Low Side Gauge - Normal, then sometimes drops to
below zero.
High Side Gauge - Normal, then sometimes goes
high.
Diagnosis:
Moisture in system freezes, temporarily stopping
cycle, normal system operation returns when ice
melts.
Correction:
1. Evacuate A/C system.
2. Replace receiver-drier.
3. Remove moisture by repeatedly evacuating
system.
4. Charge system with R-134a.
5. Operate system and check performance.
9803/3280
Body & Framework
Fault Finding
leak
or
compressor
Purchased from www.WorkshopManuals.co.uk
LOW SIDE (Blue)
High
LOW SIDE - 4.9 bar (5.0 kgf/cm
HIGH SIDE - 8.3 bar (8.5 kgf/cm
LOW SIDE (Blue)
Normal to low
LOW SIDE - -2.1 bar (-2.1 kgf/cm
HIGH SIDE - 14.8 bar (15.0 kgf/cm
Section B
10 - 7
HIGH SIDE (Red)
Low
A268090
2
)(71 lbf/in
2
)
2
)(121 lbf/in
2
)
HIGH SIDE (Red)
Normal to high
A268020
2
)(-30 lbf/in
2
)
2
)(214 lbf/in
2
)
Issue 1

Advertisement

Table of Contents
loading

This manual is also suitable for:

4cx3cx214215217