Juniper M320 Hardware Manual page 142

Multiservice edge router
Hide thumbs Also See for M320:
Table of Contents

Advertisement

M320 Multiservice Edge Router Hardware Guide
Related
Documentation
114
The following example uses the estimated values in
link loss (LL) for a 2-km-long multimode link with a power budget (P
Fiber attenuation for 2 km @ 1.0 dB/km = 2 dB
Loss for five connectors @ 0.5 dB per connector = 5(0.5 dB) = 2.5 dB
Loss for two splices @ 0.5 dB per splice = 2(0.5 dB) = 1 dB
Higher-order mode loss = 0.5 dB
Clock recovery module = 1 dB
The power margin (P
) is calculated as follows:
M
P
= P
– LL
M
B
P
= 13 dB – 2 km (1.0 dB/km) – 5 (0.5 dB) – 2 (0.5 dB) – 0.5 dB [HOL] – 1 dB [CRM]
M
P
= 13 dB – 2 dB – 2.5 dB – 1 dB – 0.5 dB – 1 dB
M
P
= 6 dB
M
The following sample calculation for an 8-km-long single-mode link with a power budget
(P
) of 13 dB uses the estimated values from
B
(LL) as the sum of fiber attenuation (8 km @ 0.5 dB/km, or 4 dB) and loss for seven
connectors (0.5 dB per connector, or 3.5 dB). The power margin (P
follows:
P
= P
– LL
M
B
P
= 13 dB – 8 km (0.5 dB/km) – 7(0.5 dB)
M
P
= 13 dB – 4 dB – 3.5 dB
M
P
= 5.5 dB
M
In both examples, the calculated power margin is greater than zero, indicating that the
link has sufficient power for transmission and does not exceed the maximum receiver
input power.
Understanding Fiber-Optic Cable Signal Loss, Attenuation, and Dispersion on page 111
Table 67 on page 113
) of 13 dB:
B
Table 67 on page 113
to calculate link loss
) is calculated as
M
Copyright © 2015, Juniper Networks, Inc.
to calculate

Advertisement

Table of Contents
loading

Table of Contents