Operator Panel Error Codes - IBM pSeries 670 Service Manual

Hide thumbs Also See for pSeries 670:
Table of Contents

Advertisement

Operator Panel Error Codes

Attention:
If you replace FRUs or perform an action on an I/O subsystem and the problem is still not
corrected, go to "MAP 1542: I/O Problem Isolation" on page 261 unless you were already directed to any
MAP 154x by the error code. Otherwise call support if the action(s) for an error code do not resolve the
problem.
Attention:
If the error code that brought you to this chapter originated in the AIX error log, remember
that an error may require an additional 15 minutes to be propagated to the AIX error log.
If you replace FRUs and the problem is corrected, go to "MAP 0410: Repair Checkout" in the RS/6000
and Eserver pSeries Diagnostic Information for Multiple Bus Systems.
Error Code Description
0000 1111 At power on, failure of power-good signal from
power supply
0000 1112 At power off, failure of power-good signal from
power supply
0000 1113 While powered on, failure of power-good signal
from power supply
0000 1114 Operator panel and service processor have
been reset after main power disturbance
0000 2222 Operator panel not communicating with service
processor
0000 3333 SPCN communications error
0000 3334 I2C repeater error
0000 BBBB Time-of-day battery malfunction
Action/
Possible Failing FRU
1. Primary I/O backplane
Location: U1.18-P1-H2
2. DCAs providing power to the primary I/O
book
Locations: U1.18-P1-V1, U1.18-P1-V2
1. Primary I/O backplane
Location: U1.18-P1-H2
2. DCAs providing power to the primary I/O
book
Locations: U1.18-P1-V1, U1.18-P1-V2
1. Primary I/O backplane
Location: U1.18-P1-H2
2. DCAs providing power to the primary I/O
book
Locations: U1.18-P1-V1, U1.18-P1-V2
Informational message
1. If system cannot be powered off, reset the
service processor (via the pinhole reset or
by disconnecting then reconnecting power).
2. Primary I/O book,
Location: U1.18-P1-H2
Primary I/O book,
Location: U1.18-P1-H2
Primary I/O book,
Location: U1.18-P1-H2
Time-of-day battery
Location: U1.18-P1-H2-V1
Chapter 5. Error Code to FRU Index
351