Operator Panel Error Codes - IBM RS/6000 Enterprise Server M80 Service Manual

Hide thumbs Also See for RS/6000 Enterprise Server M80:
Table of Contents

Advertisement

Operator Panel Error Codes

Attention:
If you replace FRUs or perform an action and the problem is still not corrected, go to "MAP
1540: Minimum Configuration" on page 110 unless otherwise indicated in the tables.
If you replace FRUs and the problem is corrected, go to "MAP 0410: Repair Checkout" in RS/6000 and
Eserver pSeries Diagnostic Information for Multiple Bus Systems.
Note: Do not shut down the system if the FRU was replaced by hot swap.
Table 4. Operator Panel Error Codes
Error Code Description
0000 1111 At power on, failure of power-good signal
from power supply
0000 1112 At power off, failure of power-good signal
from power supply
0000 1113 While power on, failure of power-good signal
from power supply
0000 1114 Primary I/O drawer operator panel and
service processor have been reset after main
power disturbance
0000 2222 Primary I/O drawer operator panel not
communicating with service processor
0000 3333 SPCN communications error
0000 3334 I2C repeater error
0000 BBBB TOD battery malfunction
164
Service Guide
Action/
Possible Failing FRU
1. Primary I/O backplane
Location: U0.1-P1
2. Primary I/O power supply
Locations: U0.1-V1
U0.1-V2
1. Primary I/O backplane
Location: U0.1-P1
2. Primary I/O power supply
Locations: U0.1-V1
U0.1-V2
1. Primary I/O backplane
Location: U0.1-P1
2. Primary I/O power supply
Locations: U0.1-V1
U0.1-V2
Information message
1. If system cannot be powered off, reset
the service processor (by the pinhole
reset or by disconnecting then
reconnecting power).
2. Primary I/O drawer backplane
Location: U0.1-P1
Primary I/O backplane
Location: U0.1-P1
Primary I/O backplane
Location: UO.1-P1
TOD battery
Location: U0.1-P1-V3