Sign In
Upload
Manuals
Brands
Danfoss Manuals
Inverter Drive
FC 100 Series
Danfoss FC 100 Series Manuals
Manuals and User Guides for Danfoss FC 100 Series. We have
8
Danfoss FC 100 Series manuals available for free PDF download: Programming Manual, Operating Instructions Manual, Instruction Manual, Manual, Design Manual
Danfoss FC 100 Series Programming Manual (253 pages)
HVAC Drive
Brand:
Danfoss
| Category:
DC Drives
| Size: 7.15 MB
Table of Contents
Table of Contents
2
1 Introduction
6
Copyright, Limitation of Liability and Revision Rights
6
Approvals
6
Symbols
6
Abbreviations
7
Definitions
8
2 How to Program
12
Local Control Panel
12
How to Operate the Graphicallcp (GLCP)
12
How to Operate Numeric LCP (NLCP)
16
Quick Menu Mode
18
Function Set-Ups
20
Main Menu Mode
24
3 Parameter Description
28
Parameter Selection
28
Main Menu Structure
28
Main Menu - Operation and Display - Group
29
Main Menu - Load and Motor - Group
41
Main Menu - Brakes - Group
55
AC Brake Max. Current
57
Main Menu - Reference/Ramps - Group
58
Main Menu - Limits/Warnings - Group
64
Main Menu - Digital In/Out - Group
68
Terminal 29 Digital Input
71
Main Menu - Analog In/Out - Group
81
Main Menu - Communications and Options - Group
87
Main Menu - Profibus - Group
94
Main Menu - CAN Fieldbus (Serial Communication Bus) - Group
100
Main Menu - Lonworks - Group
104
Main Menu - Smart Logic - Group
105
Main Menu - Special Functions -Group
117
Rfi
121
Main Menu - Drive Information - Group
124
Main Menu - Data Readouts - Group
130
Main Menu - Data Readouts 2 - Group
137
Main Menu - Adjustable Frequency Drive Closed-Loop - Group
139
MG11CD22 - VLT Is a Registered Danfoss Trademark
142
Main Menu - Extended Closed-Loop - Group
150
Main Menu - Appl. Functions - Group
158
Main Menu - Time-Based Functions - Group
171
Main Menu - Application Functions 2 - Group
182
Main Menu - Cascade Controller - Group
188
Main Menu - Analog I/O Option MCB 109 - Group
199
4 Troubleshooting
206
Alarm/
207
Alarm Words
210
Control Word Timeout (X) (X)
210
Warning Words
211
Extended Status Words
212
Fault Messages
213
External Fan Fault
215
Overload of Digital Output on X30/7
216
Overload of Digital Output Terminal
216
48 1.8 V Supply Low
217
AMA Calibration Failed
217
AMA Check Unom and Inom
217
AMA Internal Fault
217
AMA Interrupted by User
217
AMA Low Inom
217
AMA Motor too Big
217
AMA Motor too Small
217
AMA Parameter out of Range
217
Current Limit
217
Broken Belt
218
Clock Fault
218
Drive Initialized to Default Value
218
Dry Pump
218
End of Curve
218
Illegal FC Configuration
218
PTC 1 Safe Stop
218
Start Delayed
218
Stop Delayed
218
Locked Rotor
219
Missing Motor
219
New Type Code
219
5 Parameter Lists
220
Parameter Options
220
Default Settings
220
Table 5.1
220
Operation and Display
221
Load / Motor
223
Brakes
224
Reference / Ramps
225
Limits / Warnings
226
Digital in / out
226
Analog in / out
228
Communication and Options
229
Profibus
231
CAN Fieldbus
232
Lonworks
232
Smart Logic Controller
233
Special Functions
234
FC Information
235
Data Readouts
236
Info & Readouts
238
FC Closed-Loop
239
Ext. Closed-Loop
241
Application Functions
242
Noflow
242
Time-Based Funtions
244
Application Functions
245
Cascade Controller
246
MG11CD22 - VLT Is a Registered Danfoss Trademark
246
Advertisement
Danfoss FC 100 Series Programming Manual (284 pages)
HVAC Drive
Brand:
Danfoss
| Category:
DC Drives
| Size: 5.25 MB
Table of Contents
Table of Contents
1
1 Introduction
3
2 How to Programme
5
Local Control Panel
5
How to Operate Graphical LCP (GLCP)
5
Quick Menu Mode
13
Function Setups
16
Main Menu Mode
19
3 Parameter Description
23
Parameter Selection
23
Main Menu - Operation and Display - Group
23
Main Menu - Load and Motor - Group
39
Main Menu - Brakes - Group
50
Main Menu - Reference/Ramps - Group
53
Main Menu - Limits/Warnings - Group
60
Main Menu - Digital In/Out - Group
64
Main Menu - Analog In/Out - Group
80
Main Menu - Communications and Options - Group
89
Main Menu - Profibus - Group
98
Main Menu - CAN Fieldbus - Group
107
Main Menu - Lonworks - Group
113
Main Menu - Smart Logic - Group
115
Main Menu - Special Functions -Group
124
Main Menu - Frequency Converter Information - Group
133
Main Menu - Data Readouts - Group
141
Main Menu - Data Readouts 2 - Group
150
Main Menu - FC Closed Loop - Group
153
Main Menu - Extended Closed Loop - FC 100 - Group
165
Main Menu - Application Functions - FC 100 - Group
173
Main Menu - Time-Based Functions - FC 100 - Group
187
Main Menu - Application Functions 2 - Group
202
Main Menu - Cascade Controller - Group
209
Main Menu - Analog I/O Option MCB 109 - Group
223
4 Troubleshooting
231
Alarms and Warnings
231
Alarm Words
234
Extended Status Words
236
Fault Messages
237
Danfoss FC 100 Series Operating Instructions Manual (149 pages)
VLT HVAC Drive frequency converters
Brand:
Danfoss
| Category:
Media Converter
| Size: 3.84 MB
Table of Contents
Commissioning and Application Examples
1
Application Functions
2
Troubleshooting
2
Specifications
2
Table of Contents
1
Mechanical Installation
1
1 Introduction
3
Copyright, Limitation of Liability and Revision Rights
4
2 Safety
9
High Voltage Warning
9
Before Commencing Repair Work
10
Special Conditions
10
Avoid Unintended Start
11
Safe Stop of the Frequency Converter
11
IT Mains
13
3 Mechanical Installation
14
Before Starting
14
Mechanical Dimensions
16
4 Electrical Installation
20
How to Connect
20
Electrical Installation and Control Cables
21
Mains Wiring Overview
26
Motor Wiring Overview
32
DC Bus Connection
36
Brake Connection Option
37
Relay Connection
38
How to Test Motor and Direction of Rotation
41
Control Terminals
41
5 Commissioning and Application Examples
47
Commissioning
47
Quick Menu Mode
47
Tips and Tricks
50
Application Examples
52
Start/Stop
52
Pulse Start/Stop
52
Automatic Motor Adaptation (AMA)
53
6 How to Operate the Frequency Converter
54
How to Operate Graphical LCP (GLCP)
54
How to Operate Numeric LCP (NLCP)
58
7 How to Programme the Frequency Converter
60
How to Programme
60
Function Set-Ups
60
Commonly Used Parameters - Explanations
65
Operation and Display
97
Load / Motor
99
Brakes
100
Reference / Ramps
100
Limits / Warnings
101
Digital in / out
102
Analog in / out
103
Communication and Options
104
Profibus
105
CAN Fieldbus
106
Lonworks
106
Smart Logic Controller
107
Special Functions
108
Drive Information
109
Data Readouts
111
Info & Readouts
113
FC Closed Loop
114
Ext. Closed Loop
115
Application Functions
117
Time Based Funtions
119
Application Functions 2
120
Cascade Pack Controller
121
Analog I / O Option MCB
122
8 Troubleshooting
123
Alarms and Warnings
123
Fault Messages
127
Acoustic Noise or Vibration
133
9 Specifications
134
General Specifications
134
Special Conditions
145
Index
147
Advertisement
Danfoss FC 100 Series Instruction Manual (140 pages)
VLT HVAC Drive
Brand:
Danfoss
| Category:
Inverter Drive
| Size: 6.41 MB
Table of Contents
Table of Contents
1
How to Read this Instruction Manual
5
Approvals
6
Symbols
6
Abbreviations
7
Safety Instructions and General Warning
9
Safety Regulations FC
9
Disposal Instructions
9
High Voltage
10
Safety Instructions
10
Avoid Unintended Start
11
Safe Stop Installation
12
IT Line
13
How to Install
15
How to Get Started
15
Pre-Installation - High Power
16
Planning the Installation Site
16
Receiving the Adjustable Frequency Drive
16
Transportation and Unpacking
16
Lifting
17
Enclosures
18
Rated Power
18
Mechanical Dimensions
20
Mechanical Installation
21
Tools Needed
21
General Considerations
22
Installation in Enclosures - IP 00 / Chassis Units
32
Installation on the Wall - IP 21 (NEMA 1) and IP 54 (NEMA 12) Units
32
Floor Mounting - Pedestal Installation IP 21 (NEMA1) and IP 54 (NEMA12)
33
Gland/Conduit Entry - IP 21 (NEMA 1) and IP 54 (NEMA12)
35
IP 21 Drip Shield Installation (D1 and D2 Enclosure)
36
Field Installation of Options
36
Installation on Pedestal
46
Electrical Installation
49
MG.11.F1.22 - VLT ® Is a Registered Danfoss Trademark
49
Control Wires
49
Power Connections
50
Line Connection
59
Fuses
60
Electrical Installation, Control Terminals
63
Connection Examples
65
Start/Stop
65
Pulse Start/Stop
65
Speed Up/Slow
66
Potentiometer Reference
66
Electrical Installation - Continued
67
Electrical Installation, Control Cables
67
Switches S201, S202, and S801
69
Final Set-Up and Test
70
Additional Connections
72
Motor Thermal Protection
72
How to Program
73
Graphical (GLCP) and Numerical (NLCP) Display
73
How to Program on the Graphical LCP
73
How to Program on the Numerical Local Control Panel
74
Quick Set-Up
75
Parameter Descriptions
82
Special Functions
83
FC Information
83
Data Readouts
83
Info & Readouts
83
FC Closed-Loop
83
Application Functions
83
Time-Based Funtions
83
Cascade Controller
83
Analog I/O Option MCB
83
Parameter Options
84
General Specifications
117
Warnings and Alarms
125
Alarm and Status Messages
125
Alarms and Warnings
125
Annexes
131
MG.11.F1.22 - VLT ® Is a Registered Danfoss Trademark
131
Danfoss FC 100 Series Manual (82 pages)
DeviceNet
Brand:
Danfoss
| Category:
DC Drives
| Size: 1.11 MB
Table of Contents
Table of Contents
1
MG.33.D3.02 - VLT ® Is a Registered Danfoss Trademark
3
1 Introduction
5
Safety Note
6
Assumptions
9
Hardware
9
Background Knowledge
9
Abbreviations
11
2 How to Install
13
Cabling
13
Installation of Option in the Frequency
17
3 How to Configure the System
19
Configure the Master
21
Configure the Frequency Converter
21
4 How to Control the Frequency Converter
23
Devicenet Process Control Modes
23
I/O Assembly Instances
25
Process Data
25
ODVA Control Profile
27
Danfoss FC Control Profile
32
5 How to Access the Parameters
39
Explicit Messages
39
Object Classes
39
Devicenet Object Classes
39
Danfoss Object Classes
50
Reading/Writing to Parameters with Index
51
6 Parameters
53
Parameter List
66
Data Types Supported
67
7 Application Examples
69
Example: Working with Instance 101/151 Process
69
8 Troubleshooting
73
Table 8.2: LED: Network Status (NS)
74
Index
81
Danfoss FC 100 Series Manual (71 pages)
Brand:
Danfoss
| Category:
DC Drives
| Size: 2.65 MB
Table of Contents
Table of Contents
1
1 Copyright
3
Copyright, Limitation of Liability and Revision Rights
3
2 Safety
5
3 Introduction
7
4 How to Install
11
5 Configuration of the System
19
Configuring the System
19
Network Variable Description
22
VSD 6010 Profile
35
Network Variable Description - VSD Profile - Input
37
Network Variable Description - VSD Profile - Output
37
Network Variable Description - VSD Profile - Configuration
39
Node Object
41
Network Timer Functions
42
6 How to Control the Frequency Converter
43
How to Control the FC 100
43
Danfoss FC Control Profile
44
7 How to Access FC 100 Parameters
49
User-Defined Network Variables UNVT
49
8 Parameters
53
Parameter List
53
Parameter Group
53
Parameter Group
58
Data Types Supported by FC 100
60
9 Troubleshooting
61
Alarm Word and Warning Word
61
Extended Status Word
64
Reference Scaling
65
Network Variables - Overview
66
Danfoss FC 100 Series Manual (66 pages)
Brand:
Danfoss
| Category:
Media Converter
| Size: 2.31 MB
Table of Contents
Table of Contents
1
1 Copyright
3
Copyright, Limitation of Liability and Revision Rights
3
2 Safety
5
3 Introduction
7
4 How to Install
11
5 Configuration of the System
19
Configuring the System
19
Network Variable Description
22
VSD 6010 Profile
34
Network Variable Description - VSD Profile - Input
35
Network Variable Description - VSD Profile - Output
36
Network Variable Description - VSD Profile - Configuration
37
Node Object
39
Network Timer Functions
40
6 How to Control the Frequency Converter
41
How to Control the FC 100
41
Open Loop
41
Closed Loop
41
Danfoss FC Control Profile
42
7 How to Access FC 100 Parameters
45
User-Defined Network Variables UNVT
45
8 Parameters
49
Parameter List
49
Parameter Group
49
Parameter Group
54
Data Types Supported by FC 100
55
9 Troubleshooting
57
Alarm-, Warning and Extended Status Word
57
Alarm Words
58
Warning Words
59
Extended Status Word
60
Reference Scaling - Examples
61
Network Variables - Overview
62
Index
64
Danfoss FC 100 Series Design Manual (46 pages)
Output Filters
Brand:
Danfoss
| Category:
Industrial Electrical
| Size: 4.43 MB
Table of Contents
Table of Contents
2
1 How to Read this Design Guide
4
Abbreviations
4
2 Safety and Conformity
5
Safety Precautions
5
CE Conformity and Labelling
5
3 Introduction to Output Filters
6
Why Use Output Filters
6
Protection of Motor Insulation
6
The Output Voltage
6
Reduction of Motor Acoustic Noise
8
Reduction of High Frequency Electromagnetic Noise in the Motor Cable
9
What Are Bearing Currents and Shaft Voltages
10
Mitigation of Premature Bearing Wear-Out
10
Measuring Electric Discharges in the Motor Bearings
11
Which Filter for Which Purpose
13
Du/Dt Filters
13
Sine-Wave Filters
15
High-Frequency Common-Mode Core Kits
17
4 Selection of Output Filters
18
How to Select the Correct Output Filter
18
Product Overview
18
HF-CM Selection
20
Electrical Data - Du/Dt Filters
21
Electrical Data - Sine-Wave Filters
23
Spare Parts/Accessories
28
Cable Glands for Floor Standing Filters
28
Terminal Kits
29
Sine-Wave Filters
30
Du/Dt Filters
31
Sine-Wave Foot Print Filter
32
5 How to Install
33
Mechanical Mounting
33
Safety Requirements for Mechanical Installation
33
Mounting
33
Mechanical Installation of HF-CM
33
Earthing of Sine-Wave and Du/Dt Filters
34
Screening
34
Mechanical Dimensions
35
Sketches
35
6 How to Programme the Frequency Converter
44
Parameter Settings for Operation with Sine-Wave Filter
44
Advertisement
Related Products
Danfoss VLT HVAC Drive FC 102
Danfoss VLT HVAC Basic Drive FC 101
Danfoss VLT FC 103
Danfoss VLT HVAC Basic Drive FC 10
Danfoss FC103-110-250Kw
Danfoss VLT Flow Drive FC 111
Danfoss VLT HVAC Drive FC 131
Danfoss FC 100
Danfoss VLT AutomationDrive FC 361
Danfoss VLT FCM 340
Danfoss Categories
Controller
DC Drives
Thermostat
Control Unit
Water Pump
More Danfoss Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL