Cascade Pack Controller - Danfoss FC 100 Series Operating Instructions Manual

Vlt hvac drive frequency converters
Hide thumbs Also See for FC 100 Series:
Table of Contents

Advertisement

How to Programme the Frequ...

7.3.23 25-** Cascade Pack Controller

Par. No. # Parameter description
25-0* System Settings
25-00
Cascade Controller
25-02
Motor Start
25-04
Pump Cycling
25-05
Fixed Lead Pump
25-06
Number of Pumps
25-2* Bandwidth Settings
25-20
Staging Bandwidth
25-21
Override Bandwidth
25-22
Fixed Speed Bandwidth
25-23
SBW Staging Delay
25-24
SBW Destaging Delay
25-25
OBW Time
25-26
Destage At No-Flow
25-27
Stage Function
25-28
Stage Function Time
25-29
Destage Function
25-30
Destage Function Time
25-4* Staging Settings
25-40
Ramp Down Delay
25-41
Ramp Up Delay
25-42
Staging Threshold
25-43
Destaging Threshold
25-44
Staging Speed [RPM]
25-45
Staging Speed [Hz]
25-46
Destaging Speed [RPM]
25-47
Destaging Speed [Hz]
25-5* Alternation Settings
25-50
Lead Pump Alternation
25-51
Alternation Event
25-52
Alternation Time Interval
25-53
Alternation Timer Value
25-54
Alternation Predefined Time
25-55
Alternate if Load < 50%
25-56
Staging Mode at Alternation
25-58
Run Next Pump Delay
25-59
Run on Mains Delay
25-8* Status
25-80
Cascade Status
25-81
Pump Status
25-82
Lead Pump
25-83
Relay Status
25-84
Pump ON Time
25-85
Relay ON Time
25-86
Reset Relay Counters
25-9* Service
25-90
Pump Interlock
25-91
Manual Alternation
®
VLT
HVAC Drive Operating Instructions
Default value
[0] Disabled
[0] Direct on Line
[0] Disabled
[1] Yes
2 N/A
10 %
100 %
casco_staging_bandwidt
h (P2520)
15 s
15 s
10 s
[0] Disabled
[1] Enabled
15 s
[1] Enabled
15 s
10.0 s
2.0 s
SR
SR
0 RPM
0.0 Hz
0 RPM
0.0 Hz
[0] Off
[0] External
24 h
0 N/A
SR
[1] Enabled
[0] Slow
0.1 s
0.5 s
0 N/A
0 N/A
0 N/A
0 N/A
0 h
0 h
[0] Do not reset
[0] Off
0 N/A
®
MG.11.AD.02 - VLT
is a registered Danfoss trademark
4-set-up
Change during
operation
2 set-ups
FALSE
2 set-ups
FALSE
All set-ups
TRUE
2 set-ups
FALSE
2 set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
Conver-
Type
sion index
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Uint8
0
Uint8
0
Uint8
0
Uint8
0
Uint16
0
Uint16
0
Uint16
-
Uint8
-
Uint8
0
Uint16
-
Uint8
0
Uint16
-1
Uint16
-1
Uint16
0
Uint8
0
Uint8
67
Uint16
-1
Uint16
67
Uint16
-1
Uint16
-
Uint8
-
Uint8
74
Uint16
0
VisStr[7]
TimeOfDayWo-
0
Date
-
Uint8
-
Uint8
-1
Uint16
-1
Uint16
0
VisStr[25]
0
VisStr[25]
0
Uint8
0
VisStr[4]
74
Uint32
74
Uint32
-
Uint8
-
Uint8
0
Uint8
121
7
7