Load / Motor - Danfoss FC 100 Series Operating Instructions Manual

Vlt hvac drive frequency converters
Hide thumbs Also See for FC 100 Series:
Table of Contents

Advertisement

How to Programme the Frequ...

7.3.3 1-** Load / Motor

Par. No.
Parameter description
#
1-0* General Settings
1-00
Configuration Mode
1-03
Torque Characteristics
1-06
Clockwise Direction
1-2* Motor Data
1-20
Motor Power [kW]
1-21
Motor Power [HP]
1-22
Motor Voltage
1-23
Motor Frequency
1-24
Motor Current
1-25
Motor Nominal Speed
1-28
Motor Rotation Check
1-29
Automatic Motor Adaptation (AMA)
1-3* Adv. Motor Data
1-30
Stator Resistance (Rs)
1-31
Rotor Resistance (Rr)
1-35
Main Reactance (Xh)
1-36
Iron Loss Resistance (Rfe)
1-39
Motor Poles
1-5* Load Indep. Setting
1-50
Motor Magnetisation at Zero Speed
1-51
Min Speed Normal Magnetising [RPM]
1-52
Min Speed Normal Magnetising [Hz]
1-58
Flystart Test Pulses Current
1-59
Flystart Test Pulses Frequency
1-6* Load Depen. Setting
1-60
Low Speed Load Compensation
1-61
High Speed Load Compensation
1-62
Slip Compensation
1-63
Slip Compensation Time Constant
1-64
Resonance Dampening
1-65
Resonance Dampening Time Constant
1-7* Start Adjustments
1-71
Start Delay
1-73
Flying Start
1-77
Compressor Start Max Speed [RPM]
1-78
Compressor Start Max Speed [Hz]
1-79
Compressor Start Max Time to Trip
1-8* Stop Adjustments
1-80
Function at Stop
1-81
Min Speed for Function at Stop [RPM]
1-82
Min Speed for Function at Stop [Hz]
1-86
Trip Speed Low [RPM]
1-87
Trip Speed Low [Hz]
1-9* Motor Temperature
1-90
Motor Thermal Protection
1-91
Motor External Fan
1-93
Thermistor Source
®
VLT
HVAC Drive Operating Instructions
Default value
null
[3] Auto Energy Optim.
VT
[0] Normal
SR
SR
SR
SR
SR
SR
[0] Off
[0] Off
SR
SR
SR
SR
SR
100 %
SR
SR
30 %
200 %
100 %
100 %
0 %
SR
100 %
5 ms
0.0 s
[0] Disabled
SR
SR
5.0 s
[0] Coast
SR
SR
SR
SR
[4] ETR trip 1
[0] No
[0] None
®
MG.11.AD.02 - VLT
is a registered Danfoss trademark
4-set-up
Change during
operation
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
Conver-
Type
sion index
-
Uint8
-
Uint8
-
Uint8
1
Uint32
-2
Uint32
0
Uint16
0
Uint16
-2
Uint32
67
Uint16
-
Uint8
-
Uint8
-4
Uint32
-4
Uint32
-4
Uint32
-3
Uint32
0
Uint8
0
Uint16
67
Uint16
-1
Uint16
0
Uint16
0
Uint16
0
Int16
0
Int16
0
Int16
-2
Uint16
0
Uint16
-3
Uint8
-1
Uint16
-
Uint8
67
Uint16
-1
Uint16
-1
Uint8
-
Uint8
67
Uint16
-1
Uint16
67
Uint16
-1
Uint16
-
Uint8
-
Uint16
-
Uint8
99
7
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents