NEC Express5800 120Rj-2 User Manual page 245

Hide thumbs Also See for Express5800 120Rj-2:
Table of Contents

Advertisement

User Guide
Error
Error message
code
0B80
BMC Memory Test Failed.
0B81
BMC Firmware Code Area CRC check failed.
0B82
BMC Core Hardware failure.
0B83
BMC 1BF or 0BF check failed.
0B8B
BMC progress check timeout.
0B8C
BMC command access failed.
0B8D
Could not redirect the console - BMC Busy -
0B8E
Could not redirect the console - BMC Error -
0B8F
Could not redirect the console - BMC
Parameter Error -
0B90
BMC Platform Information Area corrupted.
0B91
BMC update firmware corrupted.
0B8A
BMC SEL area full
0B8F
Could not redirect the console BMC
Parameter Error
0B92
Internal Use Area of BMC FRU corrupted.
0B93
BMC SDR Repository empty.
0B94
IPMB signal lines do not respond.
0B95
BMC FRU device failure.
0B96
BMC SDR Repository failure.
0B97
BMC SEL device failure.
0B98
BMC RAM test error.
0B99
BMC Fatal hardware error.
0B9A
BMC not responding.
0B9B
Private I2C bus not responding.
0B9C
BMC internal exception.
0B9D
BMC A/D timeout error.
0B9E
SDR repository corrupt.
0B9F
SEL corrupt.
0BB0
SMBIOS – SROM data read error.
0BB1
SMBIOS – SROM data checksum bad.
8100
Memory Error detected in DIMM group #1.
8101
Memory Error detected in DIMM group #2.
8102
Memory Error detected in DIMM group #3.
8103
Memory Error detected in DIMM group #4.
8104
Memory Error detected in DIMM group #5.
8105
Memory Error detected in DIMM group #6.
8150
NVRAM cleared by jumper.
Table 31: POST Error Messages (Continued)
Recommended Action
Turn off the power once and then on again to start the
server. If the error cannot be corrected, contact your
service representative.
Start the SETUP and select [Server] - [Event Log
configuration] - [Clear All Error Logs] and press Enter
to clear event logs.
Turn off the power once and then on again to start the
server. If the error cannot be corrected, contact your
service representative.
This is not a fatal error. Turn off the power once and
then on again to restart the server. If the error cannot
be corrected, contact your service representative.
Turn off the power once and then on again to restart
the server. If the error cannot be corrected, contact
your service representative.
This is not a fatal error. Turn off the power once and
then on again to restart the server. If the error cannot
be corrected, contact your service representative.
Turn off the power once and then on again to start the
server. If the error cannot be corrected, contact your
service representative.
Update the RMC firmware. If the error cannot be
corrected, contact your service representative.
Turn off the power once and then on again to start the
server. If the error cannot be corrected, contact your
service representative.
Contact your service representative.
Contact your service representative to replace the
DIMM in the relevant group.
245
www.nec-computers.com

Advertisement

Table of Contents
loading

Table of Contents