Sensor (Bridge Media Entrance) Late Jam - Lexmark C950 Service Manual

Hide thumbs Also See for C950:
Table of Contents

Advertisement

5058-030
Step
Action and questions
Perform a print test. Go to
5
"PRINT TESTS" on page
Does the error remain?

401.03 Sensor (bridge media entrance) late jam

Step
Action and questions
Check the media path.
1
Is the media path free of any
media fragments?
Check the bridge unit media
2
transport rollers.
Are the bridge unit media
transport rollers free of excess
wear and contamination?
Check the sensor (bridge media
3
entrance) for proper operation.
1. Enter the Diagnostics Menu.
2. Touch SENSOR TESTS.
3. Touch FINISHER SENSOR
TESTS.
4. Touch Sensor (bridge media
entrance).
Does the display on the
operator panel change every
time the sensing area of the
above sensor is interrupted or
blocked?
Check the sensor (bridge media
4
entrance) for proper connection.
Is the above sensor properly
connected?
Check the bridge drive motor for
5
proper operation.
Caution: When
performing motor
tests, ensure that all
cover and door
interlock switches
are overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch FINISHER MOTOR
TESTS.
4. Touch Bridge unit motor.
Does the above component
operate properly?
Service Manual
2-178
Yes
Replace the finisher PCBA.
3-22.
Go to
"Finisher PCBA removal"
on page
4-281.
Yes
Go to step 2.
Go to step 3.
Go to step 5.
Replace the sensor (bridge
media entrance).
Go to
"Sensor (bridge media
entrance) removal" on
page
4-240.
Go to step 7.
No
Problem resolved
No
Remove any media or media
fragments.
Clean or replace the bridge unit
assembly.
Go to
"Bridge unit assembly
removal" on page
4-232.
Go to step 4.
Replace the connection.
Go to step 6.