Move the lower pinch guide assembly to the right.
6.
7.
Position the buffer diverter gate (B) using your finger to its upper-most position.
Front
Use a prying tool to remove the e-clip securing the buffer roll assembly (C) to the front of the finisher.
8.
9.
Remove the 6 mm bushing (D).
Front
10.
Remove the finisher diverter gate solenoid. See
page
4-275.
Loosen the two screws securing the belt tensioner bracket (E) to the finisher and move it downward, as
11.
shown.
B
A
E-clip
C
D
"Finisher diverter gate solenoid removal" on
5058-030