5058-030
Remove the developer housing.
18.
Previous
Next
Go Back
Reinstallation warning: When reinstalling the developer housing, ensure that the printhead retract levers are in
their uppermost position, or damage will occur to the machine. If the developer housing is installed correctly, the
bracket (C) can be mounted over the developer housing without any problems.