ELECTRIC STARTER
STARTER RELAY
REMOVAL/INSTALLATION
Remove the inner cover (page 3-5).
Disconnect the battery negative (-) cable and
remove the fuse box cover (page 1 6-6).
Remove the terminal bolt and disconnect the fuse
box/battery positive (+) cable.
Remove the starter relay from the fuse box.
Install the removed parts in the reverse order of
removal.
OPERATION INSPECTION
Remove the starter relay.
Check for continuity between the A and D terminals.
There should be continuity at the terminals. There
should be no continuity when the battery is con­
nected to E (+) and C (-) terminals of the starter
relay.
Check for continuity between the A and B terminals.
There should be no continuity at the terminals.
There should be continuity when the battery is con­
nected to E (+) and C (-) terminals of the starter
relay.
RELAY CIRCUIT INSPECTION
NOTE:
Make sure the main relay and relative circuit is
normal before performing this inspection.
Remove the starter relay.
Connect the fuse box/battery positive (+) cable and
negative (-) cable.
BATTERY VOLTAGE LINE
Measure the voltage between the Red/green wire
terminal of the starter relay connector and ground.
If battery voltage is present only when the ignition
switch is turned to ON, the circuit is normal.
1 8-6
c
D
E
FUSE BOX
RED/GREEN
A
B
YELLOW