HORN
INSPECTION
Disconnect the horn connectors from the horn.
Connect a 1 2V battery to the horn terminals.
The horn is normal if it sounds when the 1 2V battery
is connected across the horn terminals.
LOAD CUT RELAY
Remove the inner cover (page 3-5).
Remove the load cut relay.
Check for continuity between the A and 8 terminals.
There is usually no continuity, there should be con
tinuity when the battery is connected to C (+) and D
(-) terminals.
LIGHTS/METERS/SWITCHES
D
A
8