4.7.3.1
Flushing return count menu
Set the frequency (flushing return count) that the print head returns to the original spitting box when setting
"On Media" in the Flushing menu.
Notes
•
When increasing the flushing return count, clogging could occur while printing continuously.
Setup Item
Setting Value
Once to < 5 times > to
Return count
4.7.4 Side Margin menu
Setup Item
Count
Notes
•
When selecting "On Media" in the Flushing menu, the value of the Side Margin is set
automatically.
4.7.5 Media Initial menu
Set up whether the media width and edge will be detected when initializing the media.
Setup Item
Setting Value
OFF
Init.
Top&Width
<Width>
—
Set the flushing return count.
Example
o
999 times
o
•
—
•
Setting Value
<5 mm> to 25 mm
Set the side margin.
•
—
•
The media is not detected.
•
When media initial menu is set to "OFF", you can manually set
the media width in the media width menu.
Refer to: Media Width / Media Width menu
Detect the media width and edge while initializing the media.
Detect the media width while initializing the media.
•
[Enter] key: Save the setting value and shift to the previous hierarchy.
•
[Cancel] key: Cancel the setting value and shift to the previous
hierarchy.
Refer to: Setup menu
Once: return to the original spitting box every time the print
head goes and returns once.
5 times: return to the original spitting box every time the
print head goes and returns five times.
[Enter] key: Save the setting and shift to the previous
hierarchy.
[Cancel] key: Cancel the setting and shift to the previous
hierarchy.
Description
[Enter] key: Save the setting value and shift to the previous
hierarchy.
[Cancel] key: Cancel the setting value and shift to the
previous hierarchy.
Refer to: Setup menu
Description
Notes
82
User's Guide Océ CS9160 printer
Description
AP-40790 – Rev 2.0 -23/08/2011,