3.1 INSTALLATION ENVIRONMENT

Be sure to read and understand the safety warnings before handling the printer.

3.1.1 Environmental conditions for installation

Floor strength of the installation place
Power Specifications
Environmental conditions
Notes
Concerning temperature and humidity, avoid:
Places where temperature or humidity change rapidly, even though within the required
o
conditions.
Places that receive direct sunlight, increased illumination or direct air, for example from an
o
air conditioner.
To keep the temperature and humidity constant, install this product in a location where the air
condition is adjustable.
Power Supply
Frequency Range
Power Capacity
Operative Condition
Guaranteed range of
printing accuracy
Change rate
Archiving environment
User's Guide Océ CS9160 printer
More than 2940 Pa (300 kg/m²)
AC90V – 132V/198V – 264V
50/60Hz ± 1Hz
Main: 8.5 A / 4.5A
Heater: 8.5 A / 4.5A
Temperature: 20°C to 32°C
Humidity: 40% to 60%, No condensation
Temperature: 22°C to 30°C
Humidity: 40% to 60%,
Temperature: within 2°C per hour
Humidity: within 5% per hour
Temperature: - 20°C to 60°C
Humidity: 20% to 80%,
No condensation ( Ink unfilled)
28
AP-40790 – Rev 2.0 -23/08/2011,