Igniter (Turbo) Inspection - Mazda 626 MX-6 Workshop Manual

1988
Table of Contents

Advertisement

86U05X-065
©
©
86U05X-067
IGNITER (Turbo)
INSPECTION
Warning
While checking the igniter, disconnect the
connector from the ignition coil.
1. Disconnect the igniter connector.
2. Connect the SST between the igniter and igniter
connector.
Caution
Do not misconnect the ohmmeter leads.
Connect as follows:
+ lead to ground
- lead to SST
3. Connect an ohmmeter between the SST and
ground and set the scale change dial to X1.
4. Connect the SST to the battery.
5. Turn the ignition switch ON.
6. Push up the " SW2" switch on the SST while ob­
serving the ohmmeter.
79G05-010
7. The pointer needle on the ohmmeter should jump
up the the approx. 1/2 scale and then return.
8. Replace the igniter, if necessary.
IGNITER 5
5-41