Figure 13. Power supply status LEDs
LED
1
Input status LED
Off
On, green
2
Output status LED
Off
Blinking, green (about one
flash every two seconds)
Blinking, green (about two
flashes per second)
On, green
3
Fault LED
Off
On, amber

AnyRAID adapter, RAID card, and pass-through board

This topic provides information to help you locate the connectors on the AnyRAID adapter, RAID card,
and pass-through board.
The AnyRAID adapter and RAID card provide advanced SATA/SAS hardware RAID functions. The
pass-through board provides SATA software RAID functions. You can purchase a supported AnyRAID
adapter, RAID card, or pass-through board from the Lenovo Web site at:
http://lenovoquickpick.com/usa/home/thinkserver/rack-and-tower-server
Note: The option kit for AnyRAID adapter, RAID card, or pass-through board is designed for different types
of servers and might contain additional cables that are not required for your server.
For information about the installation or replacement, refer to the following topics:
• "Replacing the AnyRAID adapter or the pass-through board" on page 143
• "Installing or removing a PCI Express card: Ethernet card, RAID card, or other supported types of PCI
Express cards" on page 84
32
ThinkServer TD350 User Guide and Hardware Maintenance Manual
3
2
1
Status
The power supply is
disconnected from the
ac power source.
The power supply is
connected to the ac power
source.
The server is off or the
power supply is not working
normally.
The power supply is in the
cold redundancy active
mode.
The power supply is in the
cold redundancy sleep mode.
The server is on and the
power supply is working
normally.
The power supply is working
normally.
The power supply has failed.
Description
No action is needed.
No action is needed.
Replace the power supply.
See "Installing or replacing a
hot-swap redundant power
supply" on page 131.
No action is needed.
No action is needed.
No action is needed.
No action is needed.
Replace the power supply.
See "Installing or replacing a
hot-swap redundant power
supply" on page 131.
Action

Advertisement