Download  Print this page

Hot-swap-drive Leds; System-fan Status Leds - Lenovo ThinkServer TD350 70DG User Manual And Hardware Maintenance Manual

Machine types: 70dg, 70dh, 70dj, 70dk, 70dl, 70dm, 70dn, and 70dq user guide.
Hide thumbs

Advertisement

Hot-swap-drive LEDs

This topic applies only to server models with hot-swap internal storage drives.
Each hot-swap storage drive has two LEDs on the front.
Figure 11. Hot-swap-drive LEDs
1
Activity LED
Off
On, green
Blinking, green
On, green
On, green
Blinking, green

System-fan status LEDs

Your server has four system fans and each system fan has one corresponding status LED on the chassis.
Remove the server cover to view the system-fan status LEDs.
Note: Depending on the model, your server might look slightly different from the illustration in this topic.
30
ThinkServer TD350 User Guide and Hardware Maintenance Manual
2
Status LED
Off
Off
Off
Blinking rapidly (about four flashes
per second), amber
On, amber
Blinking slowly (about one flash per
second), amber
Description
The drive has failed or is not present.
The drive is present but not in use.
The drive is active and data is being
transferred.
The RAID controller is identifying the
drive.
The RAID array has failed and cannot
be recovered. You must recreate a
new array.
The drive is being rebuilt.