6. Other
3. Turn ON the main power switch and sub power switch.
4. Carry out the [Cross Direction Adjustment]. If the specifications are not met, loosen the
CCD unit mounting screws and move the CCD unit in the sub scan direction as neces-
sary.
See P.454
NOTE
• Hold the CCD unit by hand when moving it. NEVER use a screwdriver or similar
tool to tap to move it, as a varied distance between the CCD sensor and lens
results.
• When CCD unit is replaced, [Scan Calibration] and [Line Mag Setting] under [Sys-
tem 2] available in Service Mode should be OFF.
130
Field Service Ver. 8.0 Jun. 2008